Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MEGAS CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MEGAS CONSTRUCTION in 6701 VERANO DR, LINCOLN, NE 68523 (NAICS 238160). OSHA activity number 345030605.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Megas Construction — free Get an email when a new federal OSHA severe-injury report for Megas Construction is published. One employer, no account, unsubscribe in one click.
Establishment
MEGAS CONSTRUCTION
Site address
6701 VERANO DR
City
LINCOLN
State
NE
ZIP
68523
Mailing
809 W AMORA DR, LINCOLN, NE 68523
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.1051 A

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 3, 2021
Penalty
Initial $4,096 · Current $4,096
29 CFR  1926.1051(a):Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided.  The employer is failing to ensure that all employees have a safe means of egress from the roof. This was most recently documented on or about November 17, 2020 at 6701 Verano Dr., Lincoln, Nebraska. Employees were accessing and egressing the roof of the residence by climbing the exposed residential construction framing.
Recent events (1)
  • — Z (S) $4096

1926.405 G02 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 3, 2021
Penalty
Initial $2,341 · Current $2,341
29 CFR  1926.405(g)(2)(iv):Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.  The employer is failing to ensure that all employees are not exposed to electrical shock hazards while utilizing extension cords attached to power tools. This was most recently documented on or about November 17, 2020 at 6701 Verano Dr., Lincoln, Nebraska. The employees were utilizing an electrical extension cord where the strain relief device had pulled away from the cord.
Recent events (1)
  • — Z (S) $2341

1926.102 A01

Repeat Gravity 5 1 instance 1 exposed
Issued
Feb 3, 2021
Penalty
Initial $5,852 · Current $5,852
29 CFR 1926.102(a)(1): Eye and face protective equipment being used did not used meet the requirements specified in Z 87.1-1968:   The employer is failing to protect employees from eye injuries associated with operating pneumatic staple guns. This was most recently documented on or about November 17, 2020 at a residential construction jobsite located at 6701 Verano Dr., Lincoln, Nebraska. Employees were operating pneumatic staple guns while performing roofing activities without the use of eye protection.  Megas Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1926.102(a)(1)), which was contained in OSHA inspection number 1424796, citation number 1, item number 1 and was affirmed as a final order on 10/02/2019, with respect to a workplace located at 830 Hickory Hill Ln, Lincoln NE 68521.
Recent events (1)
  • — Z (R) $5852

1926.501 B13

Repeat Gravity 10 1 instance 3 exposed
Issued
Feb 3, 2021
Penalty
Initial $20,480 · Current $20,480
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:   The employer is failing to protect employees from fall hazards when conducting roofing operations on a residential structure. This was most recently documented on or about November 17, 2020 at 6701 Verano Dr., Lincoln, Nebraska when employees were observed working on a residential structure. The employees where installing shingles while working at a heights of over 6 feet without fall protection.  Megas Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1926.501(b)(13)), which was contained in OSHA inspection number 1424796, citation number 1, item number 2 and was affirmed as a final order on 10/02/2019, with respect to a workplace located at 830 Hickory Hill Ln, Lincoln NE 68521.  Megas Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1926.501(b)(13)), which was contained in OSHA inspection number 1444674, citation number 1, item number 2 and was affirmed as a final order on 01/27/2020, with respect to a workplace located at 6735 Monarch Dr, Lincoln NE 68516.