Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELKHART PRODUCTS CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ELKHART PRODUCTS CORPORATION in 3265 S SCHOOL AVE, FAYETTEVILLE, AR 72701 (NAICS 332913). OSHA activity number 345061493.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Elkhart Products Corporation — free Get an email when a new federal OSHA severe-injury report for Elkhart Products Corporation is published. One employer, no account, unsubscribe in one click.
Site address
3265 S SCHOOL AVE
City
FAYETTEVILLE
State
AR
ZIP
72701
Mailing
3265 S SCHOOL AVE, FAYETTEVILLE, AR 72701
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332913
Employees
145
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 7, 2021
Abate by
Jul 1, 2021
Penalty
Initial $13,653 · Current $9,557 Reduced
29 CFR  1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   Employees perform maintenance and servicing activities including but not limited to repairs and clearing jams on equipment such as, but not limited to machine 4065.  Employees were exposed to being caught in the point of operation.  (a)  Operators clearing jams and/or removing unprocessed parts did not utilize lockout or tagout devices to isolate energy sources.  The interlocked doors did not provide adequate protection in that they were not fail-safe.    (b)  Maintenance employees performing repairs such as, but not limited to correcting sensor malfunctions did not utilize lockout or tagout devices and were not afforded adequate alternative protection when interlock keys were utilized to bypass the machine guarding.
Recent events (2)
  • — I (S) $9557.1
  • — Z (S) $13653

1910.147 D02

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 7, 2021
Abate by
Jul 1, 2021
Penalty
Initial $13,653 · Current $9,557 Reduced
29 CFR  1910.147(d)(2):  The machine or equipment was not turned off or shut down using the procedures established for the machine 4065:  On or about December 7, 2020, employees bypassed guards to conduct maintenance and repair on machine 4065 while the machine was still energized.  Employees were exposed to amputations from the point of operation.
Recent events (2)
  • — I (S) $9557.1
  • — Z (S) $13653

1910.147 D03

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 7, 2021
Abate by
Jul 1, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(3):  All energy isolating devices that are needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources:  On or about December 7, 2020, employees conducting maintenance on machine 4065 were exposed to being caught-in the machine die, in that the electrical, hydraulic, and pneumatic energy sources were not isolated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 7, 2021
Abate by
Jul 1, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(4)(i):  Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  On or about December 7, 2020, employees conducting maintenance on machine 4065 were exposed to being caught-in the machine die, in that the electrical, hydraulic, and pneumatic energy sources were not locked or tagged out.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 10 1 instance 4 exposed
Issued
Jun 7, 2021
Abate by
Jul 1, 2021
Penalty
Initial $13,653 · Current $9,557 Reduced
29 CFR  1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  Employees performed servicing and maintenance activities on machine 4065.  The employer did not ensure a periodic inspection of the energy control procedure was conducted to identify deficiencies such as, but not limited to missing statement of the intended use of the procedure, deficiencies in the verification procedures, and missing specific procedural steps for removal of the energy isolation devices.  Employees were exposed to hazards associated with the unexpected release of electrical, hydraulic, and pneumatic energy.
Recent events (2)
  • — I (S) $9557.1
  • — Z (S) $13653

View Elkhart Products Corporation's full OSHA safety record →