Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LASSITER LUMBER, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LASSITER LUMBER, LLC. in 1472 HWY 17, SILAS, AL 36919 (NAICS 321113). OSHA activity number 345124788.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lassiter Lumber, LLC. — free Get an email when a new federal OSHA severe-injury report for Lassiter Lumber, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1472 HWY 17
City
SILAS
State
AL
ZIP
36919
Mailing
1472 HWY 17, SILAS, AL 36919
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
37
Ownership type
A

8 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 2, 2021
Abate by
Jul 13, 2021
Penalty
Initial $9,011 · Current $5,407 Reduced
29 CFR 1910.28(b)(1)(i):  Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  a) Production  Yard Area (Green Stacker Area): On or about January 28, 2021, and at times prior; the employer required employees to perform stacking operations without fall protection on an elevated platform with unprotected sides and edges; exposing employees to fall hazards up to approximately fifteen feet (15') to the ground below.  b) Planer Mill (Trimmer Waste Belt Area): On or about January 28, 2021, and at times prior; the employer required employees to perform housekeeping/cleaning operations without fall protection on an elevated platform with unprotected sides and edges; exposing employees to fall hazards up to approximately nine feet (9') to the concrete below.
Recent events (2)
  • — I (S) $5407
  • — Z (S) $9011

1910.219 D01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 2, 2021
Abate by
Jul 13, 2021
Penalty
Initial $10,513 · Current $6,308 Reduced
29 CFR  1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):   a)  Planer Mill (Planer Drive Pulley Area): On or about January 28, 2021, and at times prior thereto the employer required employees to operate a "Planer Pulley Assembly" that was not properly guarded; exposing employees to amputation and caught-in hazards.
Recent events (2)
  • — I (S) $6308
  • — Z (S) $10513

1910.219 E01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 2, 2021
Abate by
Jul 13, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  a)  Planer Mill (Planer Drive Belt Area): On or about January 28, 2021, and at times prior thereto the employer required employees to operate a "Planer Drive Belt Assembly" that was not properly guarded; exposing employees to amputation and caught-in hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.265 C18 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 2, 2021
Abate by
Jul 13, 2021
Penalty
Initial $7,510 · Current $4,506 Reduced
29 CFR  1910.265(c)(18)(ii): Spiked live rolls on live roll conveyor(s) were not guarded:   a)  Saw Mill Yard (DeBarker Area): On or about January 28, 2021, and at times prior thereto the employer required employees to work at close proximity to spiked live rolls that were not properly guarded; exposing employees to amputation and caught-in hazards.
Recent events (2)
  • — I (S) $4506
  • — Z (S) $7510

1910.178 P01

Other-than-serious 1 instance 20 exposed
Issued
Jul 2, 2021
Abate by
Jul 13, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):   a) Production Yard (Kiln Lumber Shed Area) On or about January 28, 2021, and at times prior; the employer failed to ensure that the KALMAR Lift Truck (Model: DCG90-6; Serial No. S40400288), which was in need of repair due to a defective horn, was taken out of service until it had been restored to safe operating condition; exposing employees to struck-by hazards during forklift operations.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.265 C26 IV

Other-than-serious 1 instance 2 exposed
Issued
Jul 2, 2021
Abate by
Jul 13, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.265(c)(26)(iv): Identifying controls. Every manually operated control switch shall be properly identified and so located as to be readily accessible to the operator.   a) Production  Yard Area (Green Stacker Area): On or about January 28, 2021, and times prior, the employer failed to ensure that the control switches were properly identified and labeled for operator use; exposing employees to sawmill hazards such as but not limited to lockout/tagout accidents during service and maintenance operations.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.304 B03 I

Other-than-serious 1 instance 7 exposed
Issued
Jul 2, 2021
Abate by
Jul 13, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.304(b)(3)(i): All 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms or on rooftops did not have ground-fault circuit-interrupter protection for personnel.  a) Office Area (Bathroom): On or about January 28, 2021, and times prior, the employer failed to install a ground-fault circuit-interrupter (GFCI or GFI) receptacle in the bathroom for employee use; exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 J02 IV

Other-than-serious 1 instance 7 exposed
Issued
Jul 2, 2021
Abate by
Jul 13, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:   a) Office Area (Kitchen/Break Room): On or about January 28, 2021, and times prior, the employer failed to install a ground-fault circuit-interrupter (GFCI or GFI) receptacle in the kitchen sink for employee use; exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0