SILAS, AL —
OSHA Inspection: LASSITER LUMBER, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LASSITER LUMBER, LLC. in 1472 HWY 17, SILAS, AL 36919 (NAICS 321113). OSHA activity number 345124788.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LASSITER LUMBER, LLC.
- Site address
- 1472 HWY 17
- City
- SILAS
- State
- AL
- ZIP
- 36919
- Mailing
- 1472 HWY 17, SILAS, AL 36919
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 37
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.28 B01 I
- Issued
- Jul 2, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $9,011 · Current $5,407 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): a) Production Yard Area (Green Stacker Area): On or about January 28, 2021, and at times prior; the employer required employees to perform stacking operations without fall protection on an elevated platform with unprotected sides and edges; exposing employees to fall hazards up to approximately fifteen feet (15') to the ground below. b) Planer Mill (Trimmer Waste Belt Area): On or about January 28, 2021, and at times prior; the employer required employees to perform housekeeping/cleaning operations without fall protection on an elevated platform with unprotected sides and edges; exposing employees to fall hazards up to approximately nine feet (9') to the concrete below.
Recent events (2)
- — I (S) $5407
- — Z (S) $9011
1910.219 D01
- Issued
- Jul 2, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $10,513 · Current $6,308 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Planer Mill (Planer Drive Pulley Area): On or about January 28, 2021, and at times prior thereto the employer required employees to operate a "Planer Pulley Assembly" that was not properly guarded; exposing employees to amputation and caught-in hazards.
Recent events (2)
- — I (S) $6308
- — Z (S) $10513
1910.219 E01 I
- Issued
- Jul 2, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: a) Planer Mill (Planer Drive Belt Area): On or about January 28, 2021, and at times prior thereto the employer required employees to operate a "Planer Drive Belt Assembly" that was not properly guarded; exposing employees to amputation and caught-in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.265 C18 II
- Issued
- Jul 2, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $7,510 · Current $4,506 Reduced
General-duty citation text
29 CFR 1910.265(c)(18)(ii): Spiked live rolls on live roll conveyor(s) were not guarded: a) Saw Mill Yard (DeBarker Area): On or about January 28, 2021, and at times prior thereto the employer required employees to work at close proximity to spiked live rolls that were not properly guarded; exposing employees to amputation and caught-in hazards.
Recent events (2)
- — I (S) $4506
- — Z (S) $7510
1910.178 P01
- Issued
- Jul 2, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a) Production Yard (Kiln Lumber Shed Area) On or about January 28, 2021, and at times prior; the employer failed to ensure that the KALMAR Lift Truck (Model: DCG90-6; Serial No. S40400288), which was in need of repair due to a defective horn, was taken out of service until it had been restored to safe operating condition; exposing employees to struck-by hazards during forklift operations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.265 C26 IV
- Issued
- Jul 2, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.265(c)(26)(iv): Identifying controls. Every manually operated control switch shall be properly identified and so located as to be readily accessible to the operator. a) Production Yard Area (Green Stacker Area): On or about January 28, 2021, and times prior, the employer failed to ensure that the control switches were properly identified and labeled for operator use; exposing employees to sawmill hazards such as but not limited to lockout/tagout accidents during service and maintenance operations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 B03 I
- Issued
- Jul 2, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(3)(i): All 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms or on rooftops did not have ground-fault circuit-interrupter protection for personnel. a) Office Area (Bathroom): On or about January 28, 2021, and times prior, the employer failed to install a ground-fault circuit-interrupter (GFCI or GFI) receptacle in the bathroom for employee use; exposing employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 J02 IV
- Issued
- Jul 2, 2021
- Abate by
- Jul 13, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location: a) Office Area (Kitchen/Break Room): On or about January 28, 2021, and times prior, the employer failed to install a ground-fault circuit-interrupter (GFCI or GFI) receptacle in the kitchen sink for employee use; exposing employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Lassiter Lumber, LLC.
View Lassiter Lumber, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345124788.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.