SPENCER, WI —
OSHA Inspection: T & T QUALITY CUTTING, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of T & T QUALITY CUTTING, LLC in 104424 KARAU AVENUE, SPENCER, WI 54479 (NAICS 321113). OSHA activity number 345201024.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- T & T QUALITY CUTTING, LLC
- Site address
- 104424 KARAU AVENUE
- City
- SPENCER
- State
- WI
- ZIP
- 54479
- Mailing
- S724 KARAU AVENUE, SPENCER, WI 54479
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 38
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.219 F03
- Issued
- Sep 1, 2021
- Abate by
- Sep 30, 2021
- Penalty
- Initial $9,557 · Current $4,779 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets. a. On March 10, 2021, an employee suffered a partial amputation of the right thumb from an unguarded chain and sprocket on the Pendu Board Dealer on the four foot picket line. b. On or about April 20, 2021, employees working around the Pendu Lugged Unscrambler were exposed to ingoing nip points and caught-in hazards created by an unguarded chain and sprocket mounted underneath the infeed deck on the four foot picket line. c. On or about April 20, 2021, employees working around the transfer decks between the hew saw and six foot trim saw were exposed to ingoing nip point and caught-in hazards created by an unguarded chain and sprocket mounted underneath the transfer deck.
Recent events (2)
- — I (S) $4778.5
- — Z (S) $9557
1910.303 B07 IV
- Issued
- Sep 1, 2021
- Abate by
- Sep 30, 2021
- Penalty
- Initial $6,827 · Current $3,414 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv):There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. a. On or about April 20, 2021, the employer did not ensure that electrical conductors were protected from abrasion by broken conduit that was mounted on a beam by the Debarker. b. On or about April 20, 2021, the employer did not ensure that electrical conductors were protected from abrasion by broken conduit mounted on the conveyor leading to the Dog Ear Machine on the four foot picket line.
Recent events (2)
- — I (O) $3413.5
- — Z (S) $6827
1910.305 B02 I
- Issued
- Sep 1, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. a. On or about April 20, 2021, a receptacle box that was located in the debarker office used for the coffee maker did not have a faceplate. b. On or about April 20, 2021, a circular junction box that was located on the north wall of the Hew Saw Room used to power exhaust fans did not have the cover in place.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.305 G01 IV
- Issued
- Sep 1, 2021
- Abate by
- Sep 30, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: a. On or about April 20, 2021, the employer utilized a flexible cord as a substitute for fixed wiring for a light in the debarker area. b. On or about April 20, 2021, the employer utilized extension cords and flexible cords as a substitute for fixed wiring to power a portable heater by the 6 foot trim saw in the new addition. c. On or about April 20, 2021, the employer utilized an extension cord as a substitute for fixed wiring to power a radio on the northeast wall of the new addition.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.305 G02 II
- Issued
- Sep 1, 2021
- Abate by
- Sep 30, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced. On or about April 20, 2021, the employer had a conductor powering a light fixture in the debarker area that was not a continuous length. The flexible cord had two splices prior to connecting the light fixture.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at T & T Quality Cutting, LLC
View T & T Quality Cutting, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345201024.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.