Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MELO ROOFING INC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of MELO ROOFING INC in 7854 RESTMOOR DRIVE, BALDWINSVILLE, NY 13027 (NAICS 238160). OSHA activity number 345347736.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Melo Roofing INC — free Get an email when a new federal OSHA severe-injury report for Melo Roofing INC is published. One employer, no account, unsubscribe in one click.
Establishment
MELO ROOFING INC
Site address
7854 RESTMOOR DRIVE
City
BALDWINSVILLE
State
NY
ZIP
13027
Mailing
750 WEST GENESEE STREET, SYRACUSE, NY 13204
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 1, 2021
Penalty
Initial $4,096 · Current $3,072 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) 7854 Restmoor Drive, Baldwinsville, NY  13027, on or about 6/4/21:  Workers were installing a new roof surface on 6:12 and 8:12 pitch roofs with ground to eave heights of 8.4 and 19.4 feet without fall protection of any kind.
Recent events (2)
  • — I (S) $3072
  • — Z (S) $4096

1926.502 D15

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 1, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not  independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee:  a) 7854 Restmoor Drive, Baldwinsville, NY  13027, on or about 6/4/21:  Workers were installing roof anchors incorrectly during the abatement phase of the inspection by using too few fasteners on the device to ensure a minimum of 5,000 pounds of strength.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 1, 2021
Penalty
Initial $3,511 · Current $2,633 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) 7854 Restmoor Drive, Baldwinsville, NY  13027, on or about 6/4/21:  Workers were installing a new roof surface on 6:12 and 8:12 pitch roofs with ground to eave heights of 8.4 and 19.4 feet and accessing that roof with an extension ladder that did not extend at least 3 feet above the level being accessed.
Recent events (2)
  • — I (S) $2633.25
  • — Z (S) $3511

1926.1053 B05 I

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 1, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support):   a) 7854 Restmoor Drive, Baldwinsville, NY  13027, on or about 6/4/21:  Workers were installing a new roof surface on 6:12 and 8:12 pitch roofs with ground to eave heights of 8.4 and 19.4 feet and accessing that roof with an extension ladder that was placed at an angle of 12:12 .
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Melo Roofing INC's full OSHA safety record →