BREWERTON, NY —
OSHA Inspection: MICHAEL C. GRAHAM & SONS CONSTRUCTION
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of MICHAEL C. GRAHAM & SONS CONSTRUCTION in 5782 BARTELL ROAD, BREWERTON, NY 13029 (NAICS 238160). OSHA activity number 345365050.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MICHAEL C. GRAHAM & SONS CONSTRUCTION
- Site address
- 5782 BARTELL ROAD
- City
- BREWERTON
- State
- NY
- ZIP
- 13029
- Mailing
- 3479 STYLES ROAD, SYRACUSE, NY 13209
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Dec 14, 2021
- Penalty
- Initial $21,457 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 5782 Bartell Road, Brewerton, NY 13029, on or about 6/16/21: Workers were installing a roof on a 4:12 pitch roof with a ground to eave height of 12 feet without fall protection of any kind. b) 5782 Bartell Road, Brewerton, NY 13029, on or about 6/16/21: A worker was installing a roof onto a 2:12 pitch shed roof with a ground to eave height of 8 feet without fall protection of any kind. Michael C. Graham & Sons Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard (CFR 1926.501(b)(13)), which was contained in OSHA inspection number 1253285, citation number 2, item number 1 and was affirmed as a final order on 3/28/18, with respect to a workplace located at 797 Rt. 37, Brewerton, NY. Michael C. Graham & Sons Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard (CFR 1926.501(b)(13)), which was contained in OSHA inspection number 1253307, citation number 1, item number 1 and was affirmed as a final order on 10/5/17, with respect to a workplace located at 5504 Kathan road, Brewerton, NY.
Recent events (2)
- — I (R) $0
- — Z (R) $21457
1926.1053 B01
- Issued
- Dec 14, 2021
- Penalty
- Initial $8,583 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 5782 Bartell Road, Brewerton, NY 13029, on or about 6/16/21: Workers were installing a roof on a 4:12 pitch roof with a ground to eave height of 12 feet and using an extension ladder to access the roof that did not extend at least 3 feet above the upper landing. Michael C. Graham & Sons Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard (CFR 1926.501(b)(13)), which was contained in OSHA inspection number 1253285, citation number 1, item number 1 and was affirmed as a final order on 3/28/18, with respect to a workplace located at 797 Rt. 37, Brewerton, NY.
Recent events (2)
- — I (R) $0
- — Z (R) $8583
1926.404 B01 I
- Issued
- Dec 14, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.(a)(LOCATION)(IDENTIFY SPECIFIC EQUIPMENT AND/OR CONDITIONS)(DESCRIBE HAZARDS WHERE NECESSARY) a) 5782 Bartell Road, Brewerton, NY 13029, on or about 6/16/21: Workers were installing a roof on a residence and using various power tools where no GFI protection was provided.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Michael C. Graham & Sons Construction
View Michael C. Graham & Sons Construction's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345365050.