MANITOWOC, WI —
OSHA Inspection: FEDERAL-MOGUL PISTON RINGS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FEDERAL-MOGUL PISTON RINGS, LLC in 2318 WALDO BLVD., MANITOWOC, WI 54220 (NAICS 336310). OSHA activity number 345378673.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FEDERAL-MOGUL PISTON RINGS, LLC
- Site address
- 2318 WALDO BLVD.
- City
- MANITOWOC
- State
- WI
- ZIP
- 54220
- Mailing
- 2318 WALDO BLVD., MANITOWOC, WI 54220
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336310
- Employees
- 492
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Sep 30, 2021
- Abate by
- Feb 28, 2022
- Penalty
- Initial $13,653 · Current $8,192 Reduced
General-duty citation text
1910.212(a)(3)(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. On or about June 16, 2021, an employee was not trained to the authorized level when performing set-up activities on the IDA#231 exposing employees to accidental restart of the equipment.
Recent events (3)
- — P (S) $8191.8
- — I (S) $8191.8
- — Z (S) $13653
1910.147 D
- Issued
- Sep 30, 2021
- Abate by
- Nov 5, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about June 16, 2021, employees were exposed to machine hazards associated with moving parts when they engaged in set up activities on the IDA#231 ( Goetze AG, D-5093 Burscheid, Type: 5.271, No. 480.011/01). The employer did not ensure that employees implemented energy control application steps or provide alternative protective measures prior to allowing them to set up. The machine was not deenergized prior to the employee engaging in the servicing / maintenance activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Federal-Mogul Piston Rings, LLC
View Federal-Mogul Piston Rings, LLC's full OSHA safety record →
More inspections in this industry (NAICS 336310)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345378673.