TAMUNING, GU —
OSHA Inspection: CORAL REEF MARINE CENTER GUAM
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CORAL REEF MARINE CENTER GUAM in 167-H.E.T CALVO MEMORIAL PARK, TAMUNING, GU 96931 (NAICS 111930). OSHA activity number 345509731.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORAL REEF MARINE CENTER GUAM
- Site address
- 167-H.E.T CALVO MEMORIAL PARK
- City
- TAMUNING
- State
- GU
- ZIP
- 96931
- Mailing
- 167-H.E.T CALVO MEMORIAL PARK, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 111930
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.29 B01
- Issued
- Feb 7, 2022
- Penalty
- Initial $2,113 · Current $1,479 Reduced
General-duty citation text
29 CFR 1910.29(b)(1): The top edge height of top rails, or equivalent guardrail system members, were not 42 inches, plus or minus 3 inches, above the walking-working surface: Shop, second floor storage: The guard rail system adjacent to the stair landing was measured at 19 inches high at the center of the guard rail system. Employees were exposed to fall hazards.
Recent events (2)
- — I (S) $1479.1
- — Z (S) $2113
1910.212 A01
- Issued
- Feb 7, 2022
- Penalty
- Initial $2,113 · Current $1,479 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Shop: A Heavy Duty bench mounted drill press (Md. #FC-100) did not have a chuck guard. Employees were exposed to rotating part hazards.
Recent events (2)
- — I (S) $1479.1
- — Z (S) $2113
1910.212 B
- Issued
- Feb 7, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving. Shop: A Heavy Duty bench mounted drill press (Md. #FC-100) used for fabricating metal parts was not anchored to the work bench. Employees were exposed to struck-by hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L04 III
- Issued
- Feb 7, 2022
- Abate by
- Mar 4, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years. The employer did not evaluate fork lift operators at least once every three years as required. Employees were exposed to struck-by hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H03 IV
- Issued
- Feb 7, 2022
- Abate by
- Mar 3, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: Employees were not trained on the new label elements (i.e. pictograms and signal words) and the safety data sheet SDS information as required by the revised Hazard Communication Standard. Employees used hazardous chemicals such as but not limited to gasoline, diesel, paints, and welding gases at the work site, and were exposed to chemical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01 I
- Issued
- Feb 7, 2022
- Abate by
- Mar 3, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): At this establishment, the employer's written Hazard Communication Program did not include a complete chemical inventory list of the hazardous chemicals known to be present in the workplace. The written Hazard Communication Program did not include a complete list of hazardous chemicals used in the workplace, such as but not limited to flammable paints, fuels, and welding gases used in the shop.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 111930)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345509731.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.