Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GENPAK, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GENPAK, LLC in 26 REPUBLIC PLAZA, MIDDLETOWN, NY 10940 (NAICS 326140). OSHA activity number 345578660.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Genpak, LLC — free Get an email when a new federal OSHA severe-injury report for Genpak, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
GENPAK, LLC
Site address
26 REPUBLIC PLAZA
City
MIDDLETOWN
State
NY
ZIP
10940
Mailing
26 REPUBLIC PLAZA, MIDDLETOWN, NY 10940
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326140
Employees
150
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 25, 2022
Penalty
Initial $8,806 · Current $6,605 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:      (a) Thermoforming; thermoset printer/ "Ink printer"/"Inline Printer":  On or prior to 10/6/21, a procedure was not utilized for control of hazardous energy during servicing and maintenance activities, including but not limited to cleaning of the printer roller(s).
Recent events (2)
  • — I (S) $6604.5
  • — Z (S) $8806

1910.147 C06 I

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 25, 2022
Penalty
Initial $8,806 · Current $6,605 Reduced
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) Thermoforming; thermoset printer/ "Ink printer":  On or prior to 10/6/21, a periodic inspection of energy control procedure for the "Ink Printer" had not been conducted at least annually.
Recent events (2)
  • — I (S) $6604.5
  • — Z (S) $8806

1910.147 C06 II

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(ii):The employer did not certify that periodic inspections of the energy control procedures had been performed:    (a) Thermoforming; thermoset printer/ "Ink printer": On or prior to 10/6/21, the employer did not certify that a periodic inspection of the energy control procedure for the "Ink Printer" had not been conducted at least annually.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Genpak, LLC's full OSHA safety record →