WILMINGTON, DE —
OSHA Inspection: CIRILLO BROS, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of CIRILLO BROS, INC. in 4309-4417 LANCASTER PIKE, WILMINGTON, DE 19805 (NAICS 237310). OSHA activity number 345699805.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CIRILLO BROS, INC.
- Site address
- 4309-4417 LANCASTER PIKE
- City
- WILMINGTON
- State
- DE
- ZIP
- 19805
- Mailing
- 761 GRANTHAM LANE, NEW CASTLE, DE 19720
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237310
- Employees
- 120
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.150 C01 VIII
- Issued
- Jun 16, 2022
- Abate by
- Jul 14, 2022
- Penalty
- Initial $7,458 · Current $0 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(viii): Portable fire extinguishers were not inspected periodically in accordance with maintenance and use of portable fire extinguishers, N.F.P.A. No. 10A-1970: a) 4309-4417 Lancaster Pike Wilmington, DE. 19805: On or about December 22, 2021, the employer failed to ensure the fire extinguishers located on the utility work truck at the site were either monthly or annually inspected as required per N.F.P.A. No. 10A-1970.
Recent events (2)
- — I (S) $0
- — Z (S) $7458
1910.1200 E01
- Issued
- Jun 16, 2022
- Penalty
- Initial $11,188 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and maintain at the workplace a written hazard communication program which describes how the criteria specified in paragraphs (f), (g), & (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes items (i) and (ii) of this subparagraph: a) 4309-4417 Lancaster Pike Wilmington, DE 19805: On or about December 22, 2021, the employer did not provide or maintain a hazardous communication program to include labels and other forms of warning, safety data sheets, and employee information and training as required. ABATEMENT NOTE: A written program shall include description of how the criteria for the following will be met: 1. Labeling and other forms of warning; 2. Material Safety Data Sheets; 3. Employee information and training Additionally, a list of hazardous chemicals known to be preset in the workplace must be compiled. Methods used to inform employees of the hazards associated with non-routine tasks and the informing of contractors of workplace hazards, including a description of the labeling system used in the facility and of the availability of material safety data sheets, must also be addressed. The written program must be made available upon request.
Recent events (2)
- — I (S) $0
- — Z (S) $11188
1910.1200 E01 I
- Issued
- Jun 16, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet. a) 4309-4417 Lancaster Pike Wilmington, DE 19805: On or about December 22, 2021, the employer did not develop nor maintain a chemical inventory list identifying the hazardous chemicals being used by their employees.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Jun 16, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) 4309-4417 Lancaster Pike Wilmington, DE 19805: On or about December 22, 2021, the employer did not provide training on hazardous chemicals to be used on the site nor did the employer provide SDS sheets for the employees to reference in case there was an exposure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1153 C01
- Issued
- Jun 16, 2022
- Penalty
- Initial $13,052 · Current $9,136 Reduced
General-duty citation text
29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section: a) 4309-4417 Lancaster Pike Wilmington, DE 19805: On or about December 22, 2021, the employer failed to conduct any type of employee assessment to the exposure of respirable crystalline silica dust or schedule monitoring for the employees reasonably expected to be exposed to dust particles during and after cutting concrete stones without required engineering controls.
Recent events (2)
- — I (O) $9136.4
- — Z (S) $13052
1926.1153 E01 I
- Issued
- Jun 16, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1153(e)(1)(i): Respiratory protection was not provided where specified by Table 1 of paragraph (c) of this section: a) 4309-4417 Lancaster Pike Wilmington, DE 19805: On or about December 22, 2021, the employer failed to ensure the employees were provided respiratory protection for the cutting of concrete using a STIHL TS420, Serial Number unknown, Company ID #TR -27 saw without any type of wet methods.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.1153 E02
- Issued
- Jun 16, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1153(e)(2): Where respirator use is required by this section, the employer did not institute a respiratory protection program in accordance with 29 CFR 1910.134: a) 4309-4417 Lancaster Pike Wilmington, DE. 19805: On or about December 22, 2021, the employer failed to institute any type of respiratory protection program for the employees required to wear respirators when cutting concrete activities covered by Table-1 exposed the employees to respirable crystalline silica.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.1153 G01
- Issued
- Jun 16, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1153(g)(1):29 CFR 1926.1153(g)(1): The employer did not establish and implement a written exposure control plan that contained at least the elements of paragraph(s) 1926.1153(g)(1)(I) through (iv): a) 4309-4417 Lancaster Pike Wilmington, DE 19805: On or about December 22, 2021, the employer failed to establish or implement any type of exposure control plan for those employees exposed or potentially exposed to respirable crystalline silica (silica dust). The employer required employees to cut concrete to complete the building phase of a retaining wall the company installed.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.1153 I01
- Issued
- Jun 16, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1153(i)(1): The employer did not include respirable crystalline silica in the program established to comply with the hazard communication standard (HCS) (29 CFR 1910.1200): a) 4309-4417 Lancaster Pike Wilmington, DE 19805: On or about December 22, 2021, the employer failed to provide any type of hazard communication program (including SDS information, list of hazardous substances, and training associated) for the employees at the site. Furthermore, the employer was not able to provide a hazard communication program for review during their inspection.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Cirillo Bros, INC.
View Cirillo Bros, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237310)
More inspections in DE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345699805.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.