Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SPIERS CONSTRUCTION, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SPIERS CONSTRUCTION, LLC in EMERALD & MITCHELL, BOISE, ID 83704 (NAICS 238110). OSHA activity number 345731582.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spiers Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Spiers Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
EMERALD & MITCHELL
City
BOISE
State
ID
ZIP
83704
Mailing
15780 RACETRACK DR., CALDWELL, ID 83607
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
9
Ownership type
A

8 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 12, 2022
Abate by
Aug 5, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.  a) On or about January 18, 2022, and at times prior thereto, employees were exposed to cave-in hazards while installing a six inch sewer line and had not been provided with adequate training in the recognition of excavation hazards and/or the means to control these hazards.
Recent events (1)
  • — Z (S) $4351

1926.651 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 12, 2022
Abate by
Aug 5, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.651(c)(2):  A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.  a) On or about January 18, 2022, and at times prior thereto, employees were working to install a sewer line in an unprotected trench with nearly vertical walls and Type B soil at a depth ranging from 6 to 7 feet.  Employees jumped in and used a wall of the trench as access/egress
Recent events (1)
  • — Z (S) $0

1926.28 A

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 12, 2022
Abate by
Aug 5, 2022
Penalty
Initial $3,729 · Current $3,729
29 CFR  1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions.   a) On or about January 18, 2022 and at times prior thereto, employees were not wearing a protective helmet and exposed to overhead hazards.  b) On or about January 18, 2022 and at times prior thereto, and employee was not using eye protection when using an angle grinder.
Recent events (1)
  • — Z (S) $3729

1926.651 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 12, 2022
Abate by
Aug 5, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection by placing and keeping such materials or equipment at least 2 feet from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary was not provided.  a) On or about January 18, 2022, and at times prior thereto,  the temporary spoil was not pushed off the trench walls and observed sliding back into the unprotected 6-7 foot deep excavation.
Recent events (1)
  • — Z (S) $0

1926.300 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 12, 2022
Abate by
Aug 5, 2022
Penalty
Initial $3,108 · Current $3,108
29 CFR  1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:  a) On or about January 18, 2022, and at times prior thereto, employees were using a Dewalt DCG412 grinder without a guard and exposed to injuries such as but not  limited to kickback and/or high speed flying particles.
Recent events (1)
  • — Z (S) $3108

1926.300 C

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 12, 2022
Abate by
Aug 5, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.300(c): Employees using hand and power tools and exposed to the hazard of falling, flying, abrasive, or splashing objects, or exposed to harmful dusts, fumes, mists, vapors, or gases were not provided with the particular personal protective equipment.  a) On or about January 18, 2022 and at times prior thereto, employees were not wearing eye protection while using small hand tools such as a Dewalt DCG412 grinder in an unprotected trench.
Recent events (1)
  • — Z (S) $0

1926.651 K02

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 12, 2022
Abate by
Aug 5, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety.  a) On or about January 18, 2022, and at times prior thereto, the identified Competent Person / Lead Foreman directed employees to work in an unprotected excavation between 6 and 7 feet deep with nearly vertical walls, exposing them to cave-in hazards.  An employee was working to install  a new six inch sewer line.  The excavation had evidence of cracking and fissuring walls.
Recent events (1)
  • — Z (S) $4351

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 12, 2022
Abate by
Aug 5, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:  a) On or about January 18, 2022, and at times prior thereto, employees were exposed to cave-in hazards when working in a trench that was approximately 6 to 7 feet in depth, with nearly vertical walls.  The excavation did not have any protective system in place.
Recent events (1)
  • — Z (S) $0

View Spiers Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345731582.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.