Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: E.V. GENERAL CONSTRUCTION INC. DBA EV CONSTRUCTION & ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of E.V. GENERAL CONSTRUCTION INC. DBA EV CONSTRUCTION & ROOFING, INC. in 745 S BUFFALO GROVE ROAD, BUFFALO GROVE, IL 60089 (NAICS 238160). OSHA activity number 345757769.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch E.V. General Construction INC. DBA EV Construction & Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for E.V. General Construction INC. DBA EV Construction & Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
745 S BUFFALO GROVE ROAD
City
BUFFALO GROVE
State
IL
ZIP
60089
Mailing
416 S ELMWOOD AVE, WAUKEGAN, IL 60085
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

4 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Aug 3, 2022
Abate by
Sep 6, 2022
Penalty
Initial $349 · Current $349
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   E.V. General Construction Inc. dba EV Construction & Roofing, Inc. , failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:   Citation Number            Item Number                    Abatement Date  01                                                    01 a                                   03/21/2022  01                                                    01 b                                   03/21/2022  02                                                    01                                       03/21/2022   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $349

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 23, 2022
Abate by
Mar 21, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR  1926.451(g)(1):Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level.  a) On February 1, 2022, at the above addressed jobsite, employees conducting roofing work from a frame scaffold, eleven (11') feet above the ground, were not provided with guardrails, midrails, cross rails or other means of fall protection, thereby exposing the employees to falls.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4351

1926.451 G01 I

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 23, 2022
Abate by
Mar 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(1)(i):Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:  a) On February 1, 2022, at the above addressed jobsite, employees conducting roofing work from a ladder jack scaffold, ten (10') feet five (5") inches above the ground, were not provided with personal fall arrest system(s), thereby exposing the employees to falls.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.501 B11

Repeat Gravity 10 1 instance 2 exposed
Issued
Feb 23, 2022
Abate by
Mar 21, 2022
Penalty
Initial $8,701 · Current $8,701
29 CFR  1926.501(b)(11):Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  a) On February 1, 2022, at the above addressed jobsite, employees conducting installation of a roof on an occupied commercial property, at approximately 12 feet above the ground, were not provided personal fall arrest systems or other means of fall protection, thereby exposing the employee to fall hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.    EV  Construction and Roofing was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1, citation number 1, item number 1 and was affirmed as a final order on October 30, 2018, with respect to a workplace located at S88 W12931 Ballard Court in Muskego, Wisconsin.
Recent events (1)
  • — Z (R) $8701

View E.V. General Construction INC. DBA EV Construction & Roofing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345757769.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.