OSHA Inspection: STAINLESS FOUNDRY & ENGINEERING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STAINLESS FOUNDRY & ENGINEERING, INC. in 5110 NORTH 35TH STREET, MILWAUKEE, WI 53209 (NAICS 331513). OSHA activity number 345761738.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stainless Foundry & Engineering, INC. — free Get an email when a new federal OSHA severe-injury report for Stainless Foundry & Engineering, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5110 NORTH 35TH STREET
City
MILWAUKEE
State
WI
ZIP
53209
Mailing
5110 NORTH 35TH STREET, MILWAUKEE, WI 53209
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331513
Employees
161
Ownership type
A

9 citations on file for this inspection.

1910.28 B03 II

Serious Gravity 1 3 instances 2 exposed
Issued
Jul 18, 2022
Penalty
Initial $4,754 · Current $2,800 Reduced
29 CFR 1910.28(b)(3)(ii) Each employee is protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems;  On or about March 3, 2022, employees were exposed to tripping hazards from open floor holes in the shake-out/green sand floor area:       (a) Floor Hole #1, ~8 inches by 6 3/4 inches, and;      (b) Floor Hole #2 (with pipe), ~18 1/4 inches by 7 inches, and;      (c) Floor Hole #3, ~8 inches by 9 inches.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4754

1910.147 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Jul 18, 2022
Penalty
Initial $13,052 · Current $9,100 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) On or about February 3, 2022, the employer did not develop and implement hazardous energy control procedures for various multi-energy equipment throughout the facility, such as but not limited to the Airset Machines, mold making machines and furnaces. This exposed employees to crushing and amputation hazards.
Recent events (2)
  • — I (S) $9100
  • — Z (S) $13052

1910.178 A05

Other-than-serious Gravity 1 1 instance 4 exposed
Issued
Jul 18, 2022
Penalty
Initial $5,594 · Current $0 Reduced
29 CFR  1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered:  (a) On or about February 3, 2022, the company utilized a forklift attachment to lift parts from furnaces. The forklift was not marked properly to ensure it reflected the limitations of the forklift while operating with the attachment.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5594

1910.178 O04

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jul 18, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.178(o)(4): Trucks equipped with attachments were not operated as partially loaded trucks when handling a load.  (a) On or about February 3, 2022, the company utilized a forklift attachment to lift parts from furnaces. The forklift was not operated as partially loaded with adequate load rating.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E03 I

Repeat Gravity 5 1 instance 2 exposed
Issued
Jul 18, 2022
Penalty
Initial $7,458 · Current $0 Reduced
29 CFR  1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):  (a) On or about March 3, 2022, inclined belts on the shake-out were not guarded to prevent employees from accessing the belts when in operation, exposing employees to entanglement and caught-in hazards.
Recent events (2)
  • — I (R) $0
  • — Z (S) $7458

1910.332 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 18, 2022
Abate by
Sep 1, 2022
Penalty
Initial $13,052 · Current $9,100 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:   (a) On or about February 2, 2022,  employee(s) tasked with conducting electrical work on or around energized and deenergized electrical equipment were not effectively trained on inspection requirements of rubber insulating equipment, use of personal protective equipment (PPE), and to adequately assess the arc flash and shock hazard level of the electrical equipment to be worked on.
Recent events (2)
  • — I (S) $9100
  • — Z (S) $13052

1910.333 A

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 18, 2022
Abate by
Aug 22, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:  (a) On or about February 3, 2022, at the facility, electrical safety-related work practices were not developed and implemented to prevent and/or limit employee exposure to electrical shock and arc flash hazards when conducting work on electrical installations and/or electrical components to equipment/machinery.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 18, 2022
Abate by
Aug 22, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.335(a)(1)(ii): Protective equipment was not maintained in a safe, reliable condition and/or was not periodically inspected or tested:  (a) On or about February 3, 2022, at the facility, electrical protective equipment utilized when work on or trouble shooting live/hot electrical equipment, was not maintained and tested periodically to ensure serviceability. This exposed employees to electrical shock and arc flash hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 E01 II

Deleted Other-than-serious 1 instance 2 exposed
Issued
Jul 18, 2022
Abate by
Aug 22, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(e)(1)(ii): Electrical equipment was used when the markings giving voltage, current, wattage, or other ratings as necessary were missing.   (a) On or about February 2, 2022, the company did not conduct an Arch Flash Hazard Analysis and mark electrical installations in the facility accordingly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0