SEATTLE, WA —
OSHA Inspection: U.S. ARMY CORPS OF ENGINEERS CHITTENDEN LOCKS
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of U.S. ARMY CORPS OF ENGINEERS CHITTENDEN LOCKS in 3015 NW 54TH ST., SEATTLE, WA 98107 (NAICS 921190). OSHA activity number 345818868.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. ARMY CORPS OF ENGINEERS CHITTENDEN LOCKS
- Site address
- 3015 NW 54TH ST.
- City
- SEATTLE
- State
- WA
- ZIP
- 98107
- Mailing
- 3015 NW 54TH ST., SEATTLE, WA 98107
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 921190
- Employees
- 47
- Ownership type
- D
Citations
9 citations on file for this inspection.
1910.212 B
- Issued
- Aug 29, 2022
- Abate by
- Sep 23, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Anchoring fixed machinery. Machine designed for a fixed location was not securely anchored to prevent walking or moving. A) In the metal shop there was a Rockwell free standing drill press that was not secured to the floor. The motor for the press was on the top of the tool, had a high center of gravity, and had the potential to fall over while in operation. Employees could be struck by a falling machine tool, with fractures and contusions as likely injuries.
Recent events (1)
- — Z (S) $0
1910.215 B09
- Issued
- Aug 29, 2022
- Abate by
- Sep 23, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceeded one-fourth inch. A) In the metal shop there was a table top fixed bench grinder with its tongue guard out of adjustment, with a distance of 1 and 1/2 inches from the edge of the guard to the surface of the wheel, exposing employees to potentially being struck by any flying debris coming off of the grinding wheel.
Recent events (1)
- — Z (S) $0
1910.219 H01
- Issued
- Aug 29, 2022
- Abate by
- Sep 23, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(h)(1): All projecting keys, setscrews, and other projections in revolving parts were not removed or made flush or guarded by metal cover. A) In the machine shop, there was a 25 inch metal lathe that did not have a chuck guard in place over the headstock spindle, which exposed employees to a rotating portions of the chuck when not flush with the spindle. An employee could get caught in the spindle if they get too close to it during operation.
Recent events (1)
- — Z (S) $0
1910.176 B
- Issued
- Aug 29, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(b): Secure storage. Storage of materials were creating a hazard. A) In the painting shop there was a room used to store the paints used in spray finishing operations. Inside the storage room there were containers of muriatic acid stored in plastic cartons stored alongside the paints. Employee contact with acid or fire could result in chemical and thermal burns and possibly smoke inhalation.
Recent events (1)
- — Z (S) $0
1910.303 G02 I
- Issued
- Aug 29, 2022
- Abate by
- Sep 23, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live�parts of�electric equipment�operating at�50 volts�or more�were not�guarded against�accidental contact by�use of�approved cabinets�or other�forms of�approved enclosures. A) In the area surrounding the painting shop's spray booth one junction of the electrical system had a piece of live conduit pulled out, exposing the live wires inside. This conduit was adjacent to a walkway used by employees. Electrical contact by employee could result in involuntary muscle movement and electrical burns.
Recent events (1)
- — Z (S) $0
1910.304 B04 II B
- Issued
- Aug 29, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets a receptacle was supplying a total cord- and plug-connected load in excess of the maximum specified in Table S-4. A) In an office in warehouse 2, a standard 15 amp power strip was being used to power a coffee maker, and a microwave oven. The combined amperage of the two appliances was 18.8 amperes, which was greater than the amp rating for the power strip and the wall outlet it was plugged into. Such usage could cause a fire, with burns and smoke inhalation as the most likely injury.
Recent events (1)
- — Z (S) $0
1910.22 A01
- Issued
- Aug 29, 2022
- Abate by
- Sep 23, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition. A) The condition of work areas around many of the machine tools in the metal shop were cluttered with materials, including a large amount of metal shavings and pools of machine oil on the floor and other surfaces. Employees were exposed to slips, trips, and falls that could result in contusions or cuts from metal shavings.
Recent events (1)
- — Z (O) $0
1910.157 C01
- Issued
- Aug 29, 2022
- Abate by
- Oct 17, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): The employer did not mount, locate, and identify portable fire extinguishers so that they were readily accessible to employees without subjecting the employees to possible injury. A) In the metal shop there were fire extinguishers that were not mounted, which could lead to damage of the extinguisher. Fire extinguishers that are not in the proper location or are damaged could lead to employee burns and smoke inhalation during a fire.
Recent events (1)
- — Z (O) $0
1910.157 E03
- Issued
- Aug 29, 2022
- Abate by
- Sep 23, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): The employer did not assure that portable fire extinguishers are subjected to an annual maintenance check. A) In the metal shop and throughout the site there were fire extinguishers that were not subjected to an annual maintenance check.
Recent events (1)
- — Z (O) $0
More inspections at U.S. Army Corps of Engineers Chittenden Locks
View U.S. Army Corps of Engineers Chittenden Locks's full OSHA safety record →
More inspections in this industry (NAICS 921190)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345818868.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.