OSHA Inspection: YTT HOME IMPROVEMENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of YTT HOME IMPROVEMENT in 4800 TRANSIT ROAD, DEPEW, NY 14043 (NAICS 238160). OSHA activity number 345830160.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch YTT Home Improvement — free Get an email when a new federal OSHA severe-injury report for YTT Home Improvement is published. One employer, no account, unsubscribe in one click.
Site address
4800 TRANSIT ROAD
City
DEPEW
State
NY
ZIP
14043
Mailing
4938 GENESEE STREET, CHEEKTOWAGA, NY 14225
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 31, 2022
Penalty
Initial $2,395 · Current $2,395
29 CFR  1926.501(b)(11):Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  a) On or about 1/24/22, at the roof area of the site, Depew, NY. Employees, engaged in roofing work of a steep roof with a slope of greater than 5 in 12, including  installing roofing papers and shingles, were not protected by fall protections.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $2395

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 31, 2022
Penalty
Initial $1,796 · Current $1,796
29 CFR  1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a) On or about 1/24/22, at the roof area of the site, Depew, NY. Extension ladders, used to access the roof, did not have ladder side rails extended at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $1796

View YTT Home Improvement's full OSHA safety record →