LOCKPORT, IL —
OSHA Inspection: GREIF, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GREIF, INC. in 1225 DAVIESS AVENUE, LOCKPORT, IL 60441 (NAICS 424420). OSHA activity number 345833057.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREIF, INC.
- Site address
- 1225 DAVIESS AVENUE
- City
- LOCKPORT
- State
- IL
- ZIP
- 60441
- Mailing
- 1225 DAVIESS AVENUE, LOCKPORT, IL 60441
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424420
- Employees
- 62
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Jul 27, 2022
- Abate by
- Sep 13, 2022
- Penalty
- Initial $14,502 · Current $9,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. On or about March 8, 2022, authorized employees were required to perform servicing and/or maintenance on the blow mold machine line #8 and other operating equipment. The employer did not ensure periodic inspections of the energy control procedures were performed at least annually as required by the standard.
Recent events (2)
- — I (S) $9500
- — Z (S) $14502
1910.147 D
- Issued
- Jul 27, 2022
- Abate by
- Sep 13, 2022
- Penalty
- Initial $14,502 · Current $9,500 Reduced
General-duty citation text
29 CFR 1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):(a) a.) Production - On or about March 21, 2022, employees were exposed to machine hazards associated with moving parts when a maintenance technician sustained an amputation while holding a spacer/ part in place while another maintenance technician powered on the Blow Mold Machine Line #8. The employer failed to implement energy control application steps as the machine was not properly locked out to perform the service work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards
Recent events (2)
- — I (S) $9500
- — Z (S) $14502
More inspections at Greif, INC.
View Greif, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 424420)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345833057.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.