Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED DAIRY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of UNITED DAIRY, INC. in 508 ROANE STREET, CHARLESTON, WV 25302 (NAICS 424430). OSHA activity number 345889463.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Dairy, INC. — free Get an email when a new federal OSHA severe-injury report for United Dairy, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
UNITED DAIRY, INC.
Site address
508 ROANE STREET
City
CHARLESTON
State
WV
ZIP
25302
Mailing
508 ROANE STREET, CHARLESTON, WV 25302
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424430
Employees
530
Ownership type
A

4 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 4, 2022
Penalty
Initial $14,502 · Current $9,000 Reduced
29 CFR  1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  a) #36 Stacker: On or about April 5, 2022 and times prior, employees preformed maintenance activities such as equipment repairs on the #36 stacker.   The employees shut off the machine and removed the guard but did not apply lockout devices to the energy isolating device to control the 110V electrical and 1,000psi hydraulic pressure.
Recent events (2)
  • — I (S) $9000
  • — Z (S) $14502

1910.147 C04 II B

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 4, 2022
Abate by
Sep 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  a) United Dairy: On or about April 5, 2022 and times prior, the employer's energy control procedures did not contain specific procedural steps for controlling hazardous energy such as 110V electrical and 1000psi hydraulic energy on the #36 stacker.  The procedures only provide a basic statement to turnoff electrical power and that there may be other energy sources but does not explain the steps for shutting down or isolating all energy sources.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II C

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 4, 2022
Abate by
Sep 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(C):The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them.  a) United Dairy: On or about April 5, 2022 and times prior, the employer's energy control procedures did not specify where or how to apply and remove lockout devices when performing maintenance on the #36 stacker to control the 110V electrical and 1,000 psi hydraulic pressure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II D

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 4, 2022
Abate by
Sep 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii)(D):The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control  a)United Dairy: On or about April 5, 2022 and times prior, the employer's energy control procedures for the #36 stacker, did not contain steps to verify energy sources such as 110V electrical and 1,000psi hydraulic have been effectively controlled by lockout devices.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View United Dairy, INC.'s full OSHA safety record →