On , OSHA opened a planned safety inspection of CS WIND AMERICA INC. in 100 TOWER ROAD, PUEBLO, CO 81004 (NAICS 332312). OSHA activity number 345920227.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CS WIND AMERICA INC.
- Site address
- 100 TOWER ROAD
- City
- PUEBLO
- State
- CO
- ZIP
- 81004
- Mailing
- 100 TOWER ROAD, PUEBLO, CO 81004
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 514
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 B
- Issued
- May 9, 2022
- Penalty
- Initial $7,044 · Current $3,522 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) NE Plate prep maintenance shop: On or about April 26, 2022, and at times prior, workers were exposed to rotating machinery hazards while operating a drill press that was not firmly anchored to the floor.
Recent events (2)
- — I (S) $3522
- — Z (S) $7044
1910.215 A04
- Issued
- May 9, 2022
- Penalty
- Initial $7,044 · Current $3,522 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) NE Plate prep maintenance shop: On or about April 26, 2022, and at times prior, workers were exposed to flying debris hazards while operating a grinder with a left work rest adjusted to five-sixteenths of an inch from the grinding wheel. b) NE Plate prep maintenance shop: On or about April 26, 2022, and at times prior, workers were exposed to flying debris hazards while operating a grinder without a work rest for the right grinding wheel.
Recent events (2)
- — I (O) $3522
- — Z (S) $7044
1910.215 B09
- Issued
- May 9, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) NE Plate prep maintenance shop: On or about April 26, 2022, and at times prior, workers were exposed to flying debris hazards while operating a grinder using the left and right abrasive wheels due to missing adjustable guards that allowed the top openings to measure one half inch.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.303 B02
- Issued
- May 9, 2022
- Penalty
- Initial $10,566 · Current $5,283 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) NE Plate prep maintenance shop: On or about April 26, 2022, and at times prior, workers were exposed to electrical hazards while working in the area of a Fellowes model SS-2B-F-CB-0, relocatable power tap, listed for household use with a damages plastic enclosure while energizing industrial power tools.
Recent events (2)
- — I (O) $5283
- — Z (S) $10566
1910.304 B04 II B
- Issued
- May 9, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord and plug connected load in excess of the maximum specified in Table S-4: a) NE Plate prep maintenance shop: On or about April 26, 2022, and at times prior, workers were exposed to electrical hazards while operating the electrical power tools energized through a relocatable power tap while exceeding the table S4 maximum of 12 amps, in that connected equipment was capable of drawing more than 27.1 amps if energized at the same time.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at CS Wind America INC.
View CS Wind America INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345920227.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.