Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: F&G HOME IMPROVEMENT LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of F&G HOME IMPROVEMENT LLC in 142 BARCLAY ST, PATERSON, NJ 07503 (NAICS 238170). OSHA activity number 345967350.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch F&G Home Improvement LLC — free Get an email when a new federal OSHA severe-injury report for F&G Home Improvement LLC is published. One employer, no account, unsubscribe in one click.
Site address
142 BARCLAY ST
City
PATERSON
State
NJ
ZIP
07503
Mailing
603 N BROAD ST, ELIZABETH, NJ 07208
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.451 F01

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 28, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR  1926.451(f)(1): Scaffolds and scaffold components shall not be loaded in excess of their maximum intended loads or rated capacities, whichever is less.  a)  Building exterior/pump jack scaffold: Scaffold and Scaffold components were loaded in excess of their maximum intended loads or rated capacities. Scaffold platform was rated for 500 pounds. 2 employees weighing 200 pounds each plus 100 pounds for material,  as stated on section 21  the Manufacturer safety requirements. There were 3 employees on the pump jack scaffold, on or about 5/18/22.
Recent events (1)
  • — Z (S) $4351

1926.452 J02

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 28, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR  1926.452(j)(2):Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.   a) Pump Jack scaffold: Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom and other points as necessary, on or about 5/18/22.   According to the ALUM-A-POLE SCAFFOLDING SYSTEM SET-UP INSTRUCTIONS & IMPORTANT MANUFACTURER SAFETY REQUIREMENTS states that pump jack scaffolds above 24', in height intermediate braces are required, with a maximum of 16' vertical brace spacing anywhere on the pole or poles.
Recent events (1)
  • — Z (S) $4351

1926.502 D06 II

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 28, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR  1926.502(d)(6)(ii): Snaphooks not designed to be connected to one another were engaged to each other.  Pump jack scaffold: An employee's Snaphook was connected to another Snaphook as part of his fall protection system, on or about 5/18/22
Recent events (1)
  • — Z (S) $4351

View F&G Home Improvement LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345967350.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.