Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TWIN CITY FAN COMPANIES, LTD.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TWIN CITY FAN COMPANIES, LTD. in 101 SUNRISE RIDGE ROAD SOUTH, BROOKINGS, SD 57006 (NAICS 333413). OSHA activity number 345980643.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Twin City FAN Companies, LTD. — free Get an email when a new federal OSHA severe-injury report for Twin City FAN Companies, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
101 SUNRISE RIDGE ROAD SOUTH
City
BROOKINGS
State
SD
ZIP
57006
Mailing
101 SUNRISE RIDGE ROAD SOUTH, BROOKINGS, SD 57006
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333413
Employees
156
Ownership type
A

2 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 3 instances 10 exposed
Issued
Nov 2, 2022
Abate by
Nov 30, 2022
Penalty
Initial $14,502 · Current $14,502
29 CFR  1910.212(a)(3)(ii): Points of operation of machinery were not guarded or guards were not designed and constructed to prevent employees from having any part of their body in the danger zones during operating cycles:  (a)Twin City Fan Companies, Ltd. at 101 Sunrise Ridge Road South, Brookings, SD 57006:  On or about and at times prior to May  24, 2022, the employer did not ensure the point of operation on the Lapointe Broaching Machine, Serial Number: R124 was properly guarded to prevent employees from having any part of the their body in the danger zone during machine operations. This hazard exposed employees to crushing and amputation hazards.  (b)Twin City Fan Companies, Ltd. at 101 Sunrise Ridge Road South, Brookings, SD 57006:  On or about and at times prior to May  24, 2022, the employer did not ensure the point of operation on the Uni-Hydro Incorporated Ironworker, Model Number: 56-14, Serial Number: 3PE7009X was properly guarded to prevent employees from having any part of the their body in the danger zone during machine operations. This hazard exposed employees to crushing and amputation hazards.  (c)Twin City Fan Companies, Ltd. at 101 Sunrise Ridge Road South, Brookings, SD 57006:  On or about and at times prior to May  24, 2022, the employer did not ensure the points of operation on the Piranha Ironworker, Serial Number: P120 1062 was properly guarded to prevent employees from having any part of the their body in the danger zones during machine operations. This hazard exposed employees to crushing and amputation hazards.
Recent events (2)
  • — I (S) $14502
  • — Z (S) $14502

1910.303 B07 I

Other-than-serious Gravity 5 1 instance 25 exposed
Issued
Nov 2, 2022
Abate by
Nov 30, 2022
Penalty
Initial $8,287 · Current $5,801 Reduced
29 CFR  1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:  (a) Twin City Fan Companies, Ltd. at 101 Sunrise Ridge Road South, Brookings, SD 57006:  On or about and at times prior to May  24, 2022, the employer did not ensure that electrical equipment was effectively closed in that employees were exposed to live electrical circuits associated with one open 220-volt electrical junction box in the first welding booth located in the southwest manual welding area .  This condition exposed employees to shock and electrocution as well as fire hazards associated with exposed wiring on the electrical box.
Recent events (2)
  • — I (O) $5800.9
  • — Z (S) $8287

View Twin City FAN Companies, LTD.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345980643.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.