OSHA Inspection: BRAZOS PIPE & STEEL FABRICATORS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of BRAZOS PIPE & STEEL FABRICATORS, INC. in 3135 HWY 332 EAST, FREEPORT, TX 77541 (NAICS 331110). OSHA activity number 346038748.

Watch Brazos Pipe & Steel Fabricators, INC. — free Get an email when a new federal OSHA severe-injury report for Brazos Pipe & Steel Fabricators, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3135 HWY 332 EAST
City
FREEPORT
State
TX
ZIP
77541
Mailing
3135 HWY 332 EAST, FREEPORT, TX 77541
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331110
Employees
60
Ownership type
A

7 citations on file for this inspection.

1910.178 L01 II

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $3698.00 · Current $2219.00 Reduced
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck:  a) At the facility, where employees had not received training to operate the Toyota 8FDU30 forklift, serial number 63846.
Recent events (2)
  • — I (S) $2218.8
  • — Z (S) $3698

1910.178 L06

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  a) At the facility, where each operator of the Toyota 8FDU30 forklift had not been certified.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 P01

Serious Gravity 1 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $3698.00 · Current $2219.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s):    a) At the facility, the Toyota 8FDU30 forklift, serial number 63846 with worn rear tires was not taken out of service.
Recent events (2)
  • — I (S) $2218.8
  • — Z (S) $3698

1910.179 J03

Serious Gravity 5 2 instances 13 exposed
Issued
Abate by
Penalty
Initial $6164.00 · Current $3698.00 Reduced
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months:  a) In the structural shop, two Mid-America 3-ton overhead bridge cranes had not been inspected annually.  b) In the structural shop, the Harrington 2-ton overhead bridge crane had not been inspected annually.
Recent events (2)
  • — I (S) $3698.4
  • — Z (S) $6164

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4931.00 · Current $2959.00 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) At the structural shop, where the rotating parts of an Unibor EQ100 Magnetic Drill Press were not guarded, exposing employees to caught-in hazards.
Recent events (2)
  • — I (S) $2958.6
  • — Z (S) $4931

1910.303 F02

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3698.00 · Current $2219.00 Reduced
29 CFR  1910.303(f)(2):  Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a) Located at the main shop in front of the Miller Deltaweld 451 welding machine, the heavy-duty electrical safety switch was not labeled.  b) Located at the main shop in front of the Rigid toolbox, the heavy-duty electrical safety switch was not labeled.  c) Located at the main shop in front of the Miller welding machine, the heavy-duty electrical safety switch was not labeled.
Recent events (2)
  • — I (S) $2218.8
  • — Z (S) $3698

1910.303 G01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) Located at the main shop in front of the Miller Deltaweld 451 welding machine, where there was not sufficient space around the electrical safety switch, exposing employees to electrical hazards.  b) Located at the main shop in front of the Rigid toolbox, where there was not sufficient space around the electrical safety switch, exposing employees to electrical hazards.  c) Located at the main shop in front of the Miller welding machine, where there was not sufficient space around the electrical safety switch, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View BRAZOS PIPE & STEEL FABRICATORS, INC.'s full OSHA safety record →