1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: WILLBANKS METALS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WILLBANKS METALS, INC. in 1155 NE 28TH STREET, FORT WORTH, TX 76106 (NAICS 423510). OSHA activity number 346051006.

Watch Willbanks Metals, INC. — free Get an email when a new federal OSHA severe-injury report for Willbanks Metals, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1155 NE 28TH STREET
City
FORT WORTH
State
TX
ZIP
76106
Mailing
1155 NE 28TH STREET, FORT WORTH, TX 76106
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423510
Employees
120
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 6 instances 5 exposed
Issued
Abate by
Penalty
Initial $11747.00 · Current $7048.00 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   On or about June 29, 2022 and times prior to, the employer did not establish specific procedures for energy control,  to protect employees from unexpected releases of energy while performing maintenance and troubleshooting operations on the following machines:  (a) 600 ton press in the Brake and Laser Building. (b) 650 ton press in the Brake and Laser Building. (c) 250 ton press in the Brake and Laser Building. (d) 350 ton press in the Brake and Laser Building. (e) 1000 ton press in the Brake and Laser Building. (f) 230 ton press in the Brake and Laser Building.
Recent events (2)
  • — I (S) $7048.2
  • — Z (S) $11747

1910.303 F02

Other-than-serious 1 instance 5 exposed
Issued
Penalty
Initial $1047.00 · Current $628.00 Reduced
29 CFR  1910.303(f)(2):Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  On or about June 29, 2022 and at times prior thereto, employees were exposed to potential shock hazards due to the circuit breakers, in panel #10, not being clearly marked.
Recent events (2)
  • — I (O) $628.2
  • — Z (O) $1047

1910.305 B01 II

Other-than-serious 1 instance 5 exposed
Issued
Penalty
Initial $1047.00 · Current $628.00 Reduced
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:   On or about June 29, 2022 and at times prior thereto, maintenance employees were exposed to electric shock of 240 volts due to a missing knockout in the circuit-breaker panel #10 in the Brake and Laser Building.
Recent events (2)
  • — I (O) $628.2
  • — Z (O) $1047

View WILLBANKS METALS, INC.'s full OSHA safety record →