OAK PARK, IL —
OSHA Inspection: OAK ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OAK ROOFING, INC. in 1118 WASHINGTON BLVD, OAK PARK, IL 60302 (NAICS 238160). OSHA activity number 346065519.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OAK ROOFING, INC.
- Site address
- 1118 WASHINGTON BLVD
- City
- OAK PARK
- State
- IL
- ZIP
- 60302
- Mailing
- 220 HEMLOCK, WOOD DALE, IL 60191
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 D16
- Issued
- Nov 23, 2022
- Abate by
- Dec 20, 2022
- Penalty
- Initial $4,144 · Current $2,489 Reduced
General-duty citation text
29 CFR 1926.451(d)(16): In addition to the normal operating brake, suspension scaffold power-operated hoists and manually operated hoists did not have a braking device or locking pawl which engages automatically when a hoist makes either of the following uncontrolled movements: an instantaneous change in momentum or an accelerated overspeed: a) On July 7, 2022, employees were working from a manually operated two-point adjustable suspension scaffold that did not have a braking device or locking pawl. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $2488.8
- — Z (S) $4144
1926.451 D17
- Issued
- Nov 23, 2022
- Abate by
- Dec 20, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(d)(17): Manually operated hoists did not have a positive crank force to descend: a) On July 7, 2022, employees were working from a two-point adjustable suspension scaffold where the manually operated hoist did not have a positive crank force to descend. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 II
- Issued
- Nov 23, 2022
- Abate by
- Dec 20, 2022
- Penalty
- Initial $5,801 · Current $3,481 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system: a) On July 7, 2022, employees were exposed to fall hazards while working from a two-point adjustable suspension scaffold. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3480.6
- — Z (S) $5801
1926.451 G03 I
- Issued
- Nov 23, 2022
- Abate by
- Dec 20, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(3)(i): Vertical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion. Safe points of anchorage include structural members of buildings, but do not include standpipes, vents, other piping systems, electrical conduit, outrigger beams, or counterweights: a) On July 7, 2022, employees were connected to vertical lifelines that were not protected from abrasion. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B04 I
- Issued
- Nov 23, 2022
- Abate by
- Dec 20, 2022
- Penalty
- Initial $5,801 · Current $3,481 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a) On July 7, 2022, employees were exposed to falls hazards while working around unprotected skylights. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $3480.6
- — Z (S) $5801
1926.502 D18
- Issued
- Nov 23, 2022
- Abate by
- Dec 20, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(18): Body belts, harnesses and/or components of a personal fall arrest system were used for hoisting materials: a) On July 7, 2022, vertical life lines used for fall protection were used for hoisting tools and materials. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at OAK Roofing, INC.
View OAK Roofing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346065519.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.