OSHA Inspection: OAK ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OAK ROOFING, INC. in 1118 WASHINGTON BLVD, OAK PARK, IL 60302 (NAICS 238160). OSHA activity number 346065519.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch OAK Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for OAK Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
OAK ROOFING, INC.
Site address
1118 WASHINGTON BLVD
City
OAK PARK
State
IL
ZIP
60302
Mailing
220 HEMLOCK, WOOD DALE, IL 60191
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.451 D16

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 23, 2022
Abate by
Dec 20, 2022
Penalty
Initial $4,144 · Current $2,489 Reduced
29 CFR 1926.451(d)(16): In addition to the normal operating brake, suspension scaffold power-operated hoists and manually operated hoists did not have a braking device or locking pawl which engages automatically when a hoist makes either of the following uncontrolled movements: an instantaneous change in momentum or an accelerated overspeed:  a)  On July 7, 2022, employees were working from a manually operated two-point adjustable suspension scaffold that did not have a braking device or locking pawl.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $2488.8
  • — Z (S) $4144

1926.451 D17

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 23, 2022
Abate by
Dec 20, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.451(d)(17):  Manually operated hoists did not have a positive crank force to descend:  a)  On July 7, 2022, employees were working from a two-point adjustable suspension scaffold where the manually operated hoist did not have a positive crank force to descend.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01 II

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 23, 2022
Abate by
Dec 20, 2022
Penalty
Initial $5,801 · Current $3,481 Reduced
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system:  a)  On July 7, 2022, employees were exposed to fall hazards while working from a two-point adjustable suspension scaffold.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $3480.6
  • — Z (S) $5801

1926.451 G03 I

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 23, 2022
Abate by
Dec 20, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(3)(i): Vertical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion.  Safe points of anchorage include structural members of buildings, but do not include standpipes, vents, other piping systems, electrical conduit, outrigger beams, or counterweights:  a)  On July 7, 2022, employees were connected to vertical lifelines that were not protected from abrasion.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 23, 2022
Abate by
Dec 20, 2022
Penalty
Initial $5,801 · Current $3,481 Reduced
29 CFR 1926.501(b)(4)(i):  Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes:  a)  On July 7, 2022, employees were exposed to falls hazards while working around unprotected skylights.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $3480.6
  • — Z (S) $5801

1926.502 D18

Other-than-serious 2 instances 2 exposed
Issued
Nov 23, 2022
Abate by
Dec 20, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(18): Body belts, harnesses and/or components of a personal fall arrest system were used for hoisting materials:  a)  On July 7, 2022, vertical life lines used for fall protection were used for hoisting tools and materials.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View OAK Roofing, INC.'s full OSHA safety record →