Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GEORGIA-PACIFIC CEDAR SPRINGS LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of GEORGIA-PACIFIC CEDAR SPRINGS LLC in 12551 GEORGIA 273 WEST, CEDAR SPRINGS, GA 39832 (NAICS 322130). OSHA activity number 346234024.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Georgia-Pacific Cedar Springs LLC — free Get an email when a new federal OSHA severe-injury report for Georgia-Pacific Cedar Springs LLC is published. One employer, no account, unsubscribe in one click.
Site address
12551 GEORGIA 273 WEST
City
CEDAR SPRINGS
State
GA
ZIP
39832
Mailing
133 PEACHTREE STREET NE, ATLANTA, GA 30303
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322130
Employees
270
Ownership type
A

5 citations on file for this inspection.

1910.147 D05 II

Serious Gravity 10 1 instance 66 exposed
Issued
Jan 3, 2023
Abate by
Feb 6, 2023
Penalty
Initial $14,502 · Current $10,151 Reduced
29 CFR 1910.147(d)(5)(ii): Where there was a possibility of re-accumulation of stored energy to a hazardous level, verification of isolation was not continued until the servicing or maintenance was completed, or until the possibility of such accumulation:  a) At 12551 Georgia 273 West, Cedar Springs, GA 39832 on or about September 20, 2022, and at times prior to, the employer exposed employees to burn hazards in that verification of isolation was not completed while performing maintenance during a scheduled outage on blow tank 2.
Recent events (2)
  • — I (S) $10151
  • — Z (S) $14502

1910.147 D06

Serious Gravity 10 1 instance 66 exposed
Issued
Jan 3, 2023
Abate by
Feb 6, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:   a) At 12551 Georgia 273 West, Cedar Springs, GA 39832 on or about September 20, 2022, and at times prior to, the employer exposed employees to burn hazards in that isolation and deenergization of the equipment was not verified prior to beginning maintenance during a scheduled outage on blow tank 2.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 III

Serious Gravity 10 1 instance 66 exposed
Issued
Jan 3, 2023
Abate by
Feb 6, 2023
Penalty
Initial $12,327 · Current $8,629 Reduced
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used:  a) At 12551 Georgia 273 West, Cedar Springs, GA 39832 on or about September 20, 2022, and at times prior to, the employer exposed employees to burn hazards in that the use proper Personal Protective Equipment (PPE) was not enforced.
Recent events (2)
  • — I (S) $8629
  • — Z (S) $12327

1910.133 A01

Serious Gravity 10 1 instance 66 exposed
Issued
Jan 3, 2023
Abate by
Feb 6, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:   a) At 12551 Georgia 273 West, Cedar Springs, GA 39832 on or about September 20, 2022, and at times prior to, the employer exposed employees to burn hazards in that the use proper eye protection for Personal Protective Equipment (PPE) was not enforced.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D01 I

Serious Gravity 10 1 instance 66 exposed
Issued
Jan 3, 2023
Abate by
Feb 6, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1)(i): When the employer had assessed the workplace hazard(s) and determined that hazard(s) were present, the employer did not select and/or use the types of personal protective equipment that would protect the affected employee from the hazard(s) identified:  a) At 12551 Georgia 273 West, Cedar Springs, GA 39832 on or about September 20, 2022, and at times prior to, the employer exposed employees to burn hazards in that the use proper Personal Protective Equipment (PPE) was not enforced.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Georgia-Pacific Cedar Springs LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346234024.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.