OSHA Inspection: K.B.P. COIL COATERS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of K.B.P. COIL COATERS, INC. in 3600 E 44TH AVE, DENVER, CO 80216 (NAICS 332812). OSHA activity number 346273196.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch K.B.P. Coil Coaters, INC. — free Get an email when a new federal OSHA severe-injury report for K.B.P. Coil Coaters, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3600 E 44TH AVE
City
DENVER
State
CO
ZIP
80216
Mailing
3600 E 44TH AVE, DENVER, CO 80216
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
34
Ownership type
A

2 citations on file for this inspection.

1910.124 C03

Deleted Serious Gravity 5 1 instance 34 exposed
Issued
Feb 17, 2023
Abate by
Apr 6, 2023
Penalty
Initial $7,813 · Current $0 Reduced
29 CFR  1910.124(c)(3):A system that sounds an alarm and automatically shuts down the operation when the vapor concentration for any substance in the exhaust airstream exceeds 25% of its LFL was not installed and functional:  Coating Room: On or about October 11, 2022, and at times prior, employees were exposed to fire and explosion hazards during coating operations in that there was no system installed to alarm and shut down the operation in the event vapor concentrations exceeded 25% of the LFL in the exhaust airstream.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7813

1910.125 E04 II

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 17, 2023
Abate by
Apr 10, 2023
Penalty
Initial $4,687 · Current $2,812 Reduced
29 CFR  1910.125(e)(4)(ii):Rags and other material contaminated with liquids from dipping or coating operations were not placed in approved waste cans immediately after use:    Coating Room: On or about October 11, 2022, and at times prior, employees were exposed to fire hazards during coating operations in that used rags were re-used and not placed in the waste can after use.