Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: K.B.P. COIL COATERS INC.,

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of K.B.P. COIL COATERS INC., in 3600 E. 44TH AVENUE, DENVER, CO 80216 (NAICS 332812). OSHA activity number 347227514.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch K.B.P. Coil Coaters INC., — free Get an email when a new federal OSHA severe-injury report for K.B.P. Coil Coaters INC., is published. One employer, no account, unsubscribe in one click.
Site address
3600 E. 44TH AVENUE
City
DENVER
State
CO
ZIP
80216
Mailing
3600 E. 44TH AVENUE, DENVER, CO 80216
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
35
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 5 exposed
Issued
Jun 11, 2024
Abate by
Jul 15, 2024
Penalty
Initial $6,453 · Current $3,800 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) K.B.P. Coil Coaters Inc.: On or about January 23, 2024, and at times prior, employees were exposed to crushing and caught-in hazards while operating an unguarded Upender Machine.  The Upender machine was not equipped with a guarding mechanism to prevent the platforms from coming down while employees were in the danger zone.    b) K.B.P. Coil Coaters Inc.: On or about January 23, 2024, and at times prior, employees were exposed to caught in-hazards from rotating parts and struck-by hazards from flying chips while operating an unguarded JET Milling/Drilling Machine.  c) K.B.P. Coil Coaters Inc.: On or about January 23, 2024, and at times prior, employees were exposed to laceration and amputation hazards while operating a JET 16" Horizontal Bandsaw that was not properly guarded.  The adjustable guard on the band saw was not adjusted to minimize employee exposure to the unused section of the saw.  Approximately four inches of the unused section of the blade was unguarded.
Recent events (2)
  • — I (S) $3800
  • — Z (S) $6453

1910.303 B01

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 11, 2024
Abate by
Jul 15, 2024
Penalty
Initial $4,839 · Current $3,000 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  a) K.B.P. Coil Coaters Inc.: On or about January 23, 2024, and at times prior, employees were exposed to electrical shock and fire hazards while working near a damaged power cord that powered a band saw in the maintenance department.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4839

1910.303 G01 I

Other-than-serious 2 instances 35 exposed
Issued
Jun 11, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i):The dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive was less than indicated in Table S1:  a) K.B.P. Coil Coaters Inc.: On or about January 23, 2024, and at times prior, the employer did not ensure employees were protected from electrical and fire hazards in that, clearance around disconnect knife switch boxes were less than that specified in Table S-1. Clearance space to Panel L3, Breaker 33, was impeded by a table placed directly in front of the electrical equipment.  This condition exposed employees to the hazard of electrical shock and burns.   b)  K.B.P. Coil Coaters Inc.: On or about January 23, 2024, and at times prior, the employer did not ensure employees were protected from electrical and fire hazards in that, clearance around disconnect knife switch boxes were less than that specified in Table S-1. Clearance space to Panel LP, Breaker 21, was impeded by a pallet loaded with material placed directly in front of the electrical equipment.  This condition exposed employees to the hazard of electrical shock and burns.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02

Other-than-serious 1 instance 5 exposed
Issued
Jun 11, 2024
Abate by
Jul 15, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2):Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  a) K.B.P. Coil Coaters Inc.: On or about January 23, 2024, and at times prior, employees were exposed to electrical shock hazards while working around an uncovered electrical junction box in the wash tank area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View K.B.P. Coil Coaters INC.,'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347227514.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.