SANFORD, ME —
OSHA Inspection: GVS NORTH AMERICA
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GVS NORTH AMERICA in 63 COMMUNITY DRIVE, SANFORD, ME 04073 (NAICS 326199). OSHA activity number 346296254.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GVS NORTH AMERICA
- Site address
- 63 COMMUNITY DRIVE
- City
- SANFORD
- State
- ME
- ZIP
- 04073
- Mailing
- 63 COMMUNITY DRIVE, SANFORD, ME 04073
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 190
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.23 E01 II
- Issued
- Jan 20, 2023
- Penalty
- Initial $6,831 · Current $4,782 Reduced
General-duty citation text
29 CFR 1910.23(e)(1)(ii): The employer did not ensure that the steps and platforms of mobile ladder stands and platforms are slip resistant. Slip-resistant surfaces must be either an integral part of the design and construction of the mobile ladder stand and platform, or provided as a secondary process or operation, such as dimpling, knurling, shot blasting, coating, spraying, or applying durable slip-resistant tapes. Establishment - The employer provided rolling platforms and step stools throughout the plant to access equipment. These platforms and stools located in the waste water treatment room, by press E11B1, by press E11C1, and press in the adjacent to the machine in the back left line of 480 volt equipment, were missing rubber anti-slip feet and could move or slide when used by employees.
Recent events (2)
- — I (S) $4781.7
- — Z (S) $6831
1910.147 C07 I
- Issued
- Jan 20, 2023
- Penalty
- Initial $8,539 · Current $5,977 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees. Establishment - The employer did not provide adequate Lock Out Tag Out training. Current authorized employees had not been trained and did not follow the correct process when locking out the E11B1 Press.
Recent events (2)
- — I (S) $5977.3
- — Z (S) $8539
1910.147 F03 II D
- Issued
- Jan 20, 2023
- Penalty
- Initial $8,539 · Current $5,977 Reduced
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment. Establishment - The employer allowed an authorized maintenance employee to work on the E11B1 press without adding his personal lock to the equipment, instead the press was locked out by his supervisor.
Recent events (2)
- — I (S) $5977.3
- — Z (S) $8539
1910.303 B07 I
- Issued
- Jan 20, 2023
- Penalty
- Initial $6,831 · Current $4,782 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. Wall outside the waster water treatment room - The employer exposed employees to live electrical wiring through a missing knockout access point in an electrical junction box.
Recent events (2)
- — I (S) $4781.7
- — Z (S) $6831
1910.305 G01 IV A
- Issued
- Jan 20, 2023
- Penalty
- Initial $5,122 · Current $3,585 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. Establishment - The employer used extension cords to power the E11B1 and E11C1 machines instead of fixed wiring.
Recent events (2)
- — I (S) $3585.4
- — Z (S) $5122
1910.1200 F06
- Issued
- Jan 20, 2023
- Penalty
- Initial $5,122 · Current $3,585 Reduced
General-duty citation text
29 CFR 1910.1200(f)(6): Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either. Establishment - The employer did not ensure that secondary containers of hazardous chemicals had appropriate hazardous communication labeling. The label on a secondary container of ink thinner on the EK4 machine had inadequate labeling, it was illegible and covered by spilled ink.
Recent events (2)
- — I (S) $3585.4
- — Z (S) $5122
1910.304 B03 II C 3
- Issued
- Jan 20, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug found damaged or defective was used before being repaired. Establishment - The cord on the EK4 machine was damaged and used prior to repair. The cord was not equipped with a strain relief thus the extreme flexing/bending of the cord had caused the outer insulation to crack.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at GVS North America
View GVS North America's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346296254.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.