OSHA Inspection: NAVY EXCHANGE - NAVAL AIR WEAPONS STATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NAVY EXCHANGE - NAVAL AIR WEAPONS STATION in BUILDING 19 MAIL STOP 1325, RIDGECREST, CA 93555 (NAICS 453998). OSHA activity number 346299944.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Navy Exchange - Naval AIR Weapons Station — free Get an email when a new federal OSHA severe-injury report for Navy Exchange - Naval AIR Weapons Station is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 19 MAIL STOP 1325
City
RIDGECREST
State
CA
ZIP
93555
Mailing
BUILDING 19 STOP, RIDGECREST, CA 93555
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453998
Employees
16
Ownership type
D

4 citations on file for this inspection.

1910.304 B03 I

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 22, 2022
Abate by
Dec 12, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(3)(i): All 125-volt, single-phase, 15- and 20-ampere receptacles installed in wet locations were not equipped with ground-fault circuit-interrupter protection for personnel.  Administration Office Break Room: On an/or before October 19, 2022 employee(s) used the break room sink in close proximity (within 6 feet) to a wall outlet that was not GFCI protected. This condition potentially exposed employee(s) to electrical shock hazard(s).
Recent events (1)
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 22, 2022
Abate by
Dec 12, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  Store Managers Office: On and/or before October 18, 2022 employee(s) used the office for administration duties. An office wall outlet was under electrical power and missing the faceplate. This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV B

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 22, 2022
Abate by
Jan 11, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables may not be used where run through holes in walls, ceilings or floors:  Store Floor/ Wisconsin Cheese Cold Display: a temporary white coiled extension cord used to power the cold cheese display was run through an opening in a ceiling tile. Employee(s) were exposed to potential electrical shock and/or fire hazard(s).
Recent events (1)
  • — Z (S) $0

1910.303 B02

Repeat Gravity 5 1 instance 2 exposed
Issued
Nov 22, 2022
Abate by
Jan 11, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Store/Register Area: On and/or before October 19, 2022 a chest freezer used to store consumables for purchase was plugged into a relocatable power tap and not used according to listing and labeling instructions.  This condition potentially exposed employee(s) to electrical shock and/or fire hazard(s).  The Navy Exchange was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303(b)(2), which was contained in OSHA inspection number 1623647, citation number 1, item number 1 and was affirmed as a final order on October 25, 2022, with respect to a workplace located at NAS North Island Building 2017 San Diego, CA. 92135.
Recent events (1)
  • — Z (R) $0

View Navy Exchange - Naval AIR Weapons Station's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346299944.