KAUKAUNA, WI —
OSHA Inspection: NOTT COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NOTT COMPANY in 3100 EAST FRONTAGE RD., KAUKAUNA, WI 54130 (NAICS 332912). OSHA activity number 346317720.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NOTT COMPANY
- Site address
- 3100 EAST FRONTAGE RD.
- City
- KAUKAUNA
- State
- WI
- ZIP
- 54130
- Mailing
- 4480 ROUND LAKE ROAD WEST, ARDEN HILLS, MN 55112
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332912
- Employees
- 25
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C04 II
- Issued
- Jan 27, 2023
- Abate by
- Mar 6, 2023
- Penalty
- Initial $10,046 · Current $5,023 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: a) At an establishment located at 3100 East Frontage Road in Kaukauna, Wisconsin in the Assembly Area; the energy control procedures did not not clearly and specifically outline the purpose and scope of the procedure for the installation of the guide tubes, die blocks, sleeves, and the changing of the blade for the Marken Model 475A and the Marken Model 550 w/ D.M. hose cutter equipment. b) At an establishment located at 3100 East Frontage Road in Kaukauna, Wisconsin in the Assembly Area; the energy control procedures did not identify all applicable energy sources including but not limited to pneumatic power on the Marken Model 475A and Marken Model 550 w/ D.M. hose cutter equipment.
Recent events (2)
- — I (S) $5023
- — Z (S) $10046
1910.147 C06 I
- Issued
- Jan 27, 2023
- Abate by
- Mar 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. On or about October 1, 2022, at an establishment located at 3100 East Frontage Road, in Kaukauna, Wisconsin in the Assembly Area; the employer had not accomplished a periodic inspection of the lockout / tagout procedures and the authorized employees for the Marken Model 550 w/DM and Marken Model 475A hose cutters which were put into service October 1, 2021.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- Jan 27, 2023
- Abate by
- Mar 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. On or about the week of October 17, 2022, at an establishment located at 3100 East Frontage Road, in Kaukauna, Wisconsin in the Assembly Area; the employer did not provide training to recognize all applicable hazardous energy sources as well as the means and methods to accomplish proper energy isolating steps exposing employees to accidental or inadvertent restart of the equipment while performing servicing and maintenance work including the installation of the guide tubes, die blocks, sleeves, or changing of the blade.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D
- Issued
- Jan 27, 2023
- Abate by
- Mar 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) During the week of October 17, 2022, at an establishment located at 3100 East Frontage Road, in Kaukauna, Wisconsin in the Assembly Area; employees were exposed to machine hazards associated with moving parts when they engaged in blade changes activities on the Marken Model 475A. The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to perform blade changes. The machine was not deenergized prior to the employee engaging in the servicing / maintenance activity. (b) On or about October 31, 2022 and thereafter, at an establishment located at 3100 East Frontage Road, in Kaukauna, Wisconsin in the Assembly Area; employees were exposed to machine hazards associated with moving parts when they engaged in setup activities on the Model: 550 w/D.M., S/N: 3078. The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to perform setup activities. The machine was not deenergized prior to the employee engaging in the servicing / maintenance activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L02 II
- Issued
- Jan 27, 2023
- Penalty
- Initial $10,046 · Current $5,023 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(ii): Training shall consist of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. On or about November 1, 2022, at an establishment located at 3100 East Frontage Road, in Kaukauna, Wisconsin; the employer did not provide training and evaluations of the forklift operator(s) to ensure the operator could operate safely.
Recent events (2)
- — I (S) $5023
- — Z (S) $10046
1910.178 Q07
- Issued
- Jan 27, 2023
- Abate by
- Mar 6, 2023
- Penalty
- Initial $10,046 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported and corrected. On or about November 1, 2022, at an establishment located at 3100 East Frontage Road, in Kaukauna, Wisconsin in the Assembly Area; the green Clark Electric Forklift TMX 15s was not inspected on a daily basis to ensure no adverse conditions were present which could affect the safety of the equipment exposing employees to struck by or tipping hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $10046
1910.303 B02
- Issued
- Jan 27, 2023
- Abate by
- Mar 6, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. During the week of October 17, 2022, at an establishment located at 3100 East Frontage Road, in Kaukauna, Wisconsin in the Assembly Area; quad metallic electrical pedant boxes were suspended used to plug in various equipment and not surface mounted exposing employees to electrical shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Nott Company
View Nott Company's full OSHA safety record →
More inspections in this industry (NAICS 332912)
More inspections in WI