Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MILK SPECIALTIES GLOBAL

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MILK SPECIALTIES GLOBAL in 325 TOMPKINS STREET, FOND DU LAC, WI 54935 (NAICS 311514). OSHA activity number 346354111.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Milk Specialties Global — free Get an email when a new federal OSHA severe-injury report for Milk Specialties Global is published. One employer, no account, unsubscribe in one click.
Site address
325 TOMPKINS STREET
City
FOND DU LAC
State
WI
ZIP
54935
Mailing
325 TOMPKINS STREET, FOND DU LAC, WI 54935
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311514
Employees
125
Ownership type
A

2 citations on file for this inspection.

1910.119 D03 I B

Deleted Serious Gravity 5 6 instances 125 exposed
Issued
May 5, 2023
Abate by
Jun 27, 2023
Penalty
Initial $11,162 · Current $0 Reduced
29 CFR  1910.119(d)(3)(i)(B): The employer shall complete a compilation of written process safety information before conducting any process hazard analysis required by the standard.  This process safety information shall include information pertaining to the equipment in the process including piping and instrument diagrams (P&ID's):  On or about February 14, 2023, at the establishment located at 325 Tompkins Street Fond Du Lac, Wisconsin;  the employer did not have a complete compilation of process safety information pertaining to the equipment in the process including piping and instrument diagrams.  Deficiencies in the completeness of the ammonia refrigeration system (ARS) and its associated P&IDs included, but were not limited to, the following:  a) Compressor Room East, the Vilter High Stage Compressor, model number VMC440, identified as "CP-1", was labeled "CP-1 Vilter 446" on P&ID R111-02_EAST ENGINE ROOM.  b) Compressor Room East, the Vilter High Stage Compressor model number 4512XLB, identified as "CP-2", was equipped with a hand valve that was missing a tag.  The hand valve was labeled "CP-2 HV009" on P&ID R111-02_EAST ENGINE ROOM.  c) Compressor Room East, the Vilter High Stage Compressor model number 4512XL, identified as "CP-3", was equipped with a pressure indicator labeled "CP-3 PI 001" that was not labeled on P&ID R111-03_EAST ENGINE ROOM.  d) Compressor Room East, the Frick High Stage Compressor model number RXF50H, identified as "CP-4", was equipped with a hand valve labeled as "CP-4 HV003" that was identified as "CP-5 HV 003" on P&ID R111-03_EAST ENGINE ROOM.  e) South-east Silo Room, the horizontal tank identified as "TK-5101", was no longer in service and was not removed from P&ID R111-08_SOUTH-EAST SILO ROOM.  f) South-east Silo Room, the horizontal tank identified as "TK-5102", was no longer in service and was not removed from P&ID R111-08_SOUTH-EAST SILO ROOM.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11162

1910.119 D03 II

Other-than-serious Gravity 5 1 instance 125 exposed
Issued
May 5, 2023
Abate by
Aug 1, 2023
Penalty
Initial $0 · Current $5,000
29 CFR  1910.119(d)(3)(ii):  The employer shall document that equipment complies with recognized and generally accepted good engineering practices:  On or about February 14, 2023, at the establishment located at 325 Tompkins Street Fond Du Lac, Wisconsin; the employer failed to document compliance with the employer's chosen RAGAGEP including 1991 IIAR Bulletin 114, "Identification of Ammonia Refrigeration piping and system components" when Plate and Frame Heat Exchanger Surge Drum labeled as "V-34" was identified "V-32" on P&ID R111-20_GC-4 AREA.  This hazardous condition exposed employees to inhalation hazards and burns from anhydrous ammonia liquid and vapors.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $0

View Milk Specialties Global's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346354111.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.