Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HOME MARKET FOODS, INC.

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of HOME MARKET FOODS, INC. in 140 MORGAN DRIVE, NORWOOD, MA 02062 (NAICS 311412). OSHA activity number 346407141.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Home Market Foods, INC. — free Get an email when a new federal OSHA severe-injury report for Home Market Foods, INC. is published. One employer, no account, unsubscribe in one click.
Site address
140 MORGAN DRIVE
City
NORWOOD
State
MA
ZIP
02062
Mailing
140 MORGAN DRIVE, NORWOOD, MA 02062
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311412
Employees
410
Ownership type
A

22 citations on file for this inspection.

1910.119 C02

Deleted Serious Gravity 5 1 instance 203 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $12,278 · Current $0 Reduced
29 CFR 1910.119(c)(2):  Employer did not consult with employees and their representatives on the conduct and development of process hazards analyses and on the development of the other elements of process safety management in this standard.  Establishment:  On or about December 19, 2022, the employer did not consult with employees in the conduct and development of process hazard analyses and on the development of the other elements of process safety management in this standard including, but not limited to, the compliance audit conducted on or about September 2022.
Recent events (3)
  • — F (S) $0
  • — C (S) $12278
  • — Z (S) $12278

1910.119 D03 II

Deleted Serious Gravity 10 4 instances 410 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR 1910.119(d)(3)(ii): Employer did not document that equipment complies with recognized and generally accepted good engineering practices (RAGAGEP).   Establishment:  a)  The employer did not document that equipment complied with its chosen recognized and generally accepted good engineering practice (RAGAGEP), such as ANSI/IIAR (American National Safety Institute/International Institute of Ammonia Refrigeration) 2 - 2014 edition, Section 6.13.2.3 when emergency mechanical ventilation in the ammonia machine room (AMR) did not automatically activate when detection of ammonia concentrations exceeded 150 parts per million (one half the Immediately Dangerous to Life and Health).  b)  The employer did not document that equipment complied with its chosen recognized and generally accepted good engineering practice (RAGAGEP), such as ANSI/IIAR (American National Safety Institute/International Institute of Ammonia Refrigeration) 2 - 2014 edition, Section 6.6.2, when pipes penetrating the ammonia machinery room separation were not sealed to the wall to which they penetrated.   c) The employer did not document that equipment complied with its chosen recognized and generally accepted good engineering practice (RAGAGEP), such as ANSI/IIAR (American National Safety Institute/International Institute of Ammonia Refrigeration) 2 - 2014 edition, Section 6.7 when eyewash and body shower were not located external to the Engine (Machine) Room and readily accessible via an exit.   d) The employer did not document that equipment complied with its chosen recognized and generally accepted good engineering practice (RAGAGEP), such as ANSI/IIAR 2-2014 edition, Section 6.13.1.2 when ammonia leak detector did not activate an alarm that reported to a monitored location so corrective action can be taken at or above 25 ppm.  On or about December 19, 2022, an uncontrolled release of approximately 21,000 pounds of anhydrous ammonia refrigerant occurred in the ammonia engine room where two employees were working resulting in one employee who was fatally injured and one employee who was seriously injured.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.119 F01 I D

Serious Gravity 5 1 instance 203 exposed
Issued
Jun 16, 2023
Abate by
Dec 31, 2024
Penalty
Initial $12,278 · Current $12,278
29 CFR  1910.119(f)(1)(i)(D): The employer did not develop and implement written operating procedures that provide clear instructions for emergency shutdown, including the conditions under which emergency shutdown is required, and the assignment of shutdown responsibility to qualified operators to ensure that emergency shutdown is executed in a safe and timely manner.  Establishment:  On or about December 19, 2022, the employer did not implement effective emergency shut down procedures of the ammonia refrigeration equipment in that the operating procedures did not provide clear instructions for shutdown of ammonia refrigeration equipment in the event of an uncontrolled release.
Recent events (5)
  • — P (S) $12278
  • — P (S) $12278
  • — F (S) $12278

1910.119 F04

Serious Gravity 5 1 instance 20 exposed
Issued
Jun 16, 2023
Abate by
Dec 31, 2024
Penalty
Initial $12,278 · Current $12,278
29 CFR 1910.119(f)(4): Employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel:   Establishment:  Employer did not develop and implement safe work practices to provide for the control of hazards during operations including, but not limited to, the use of scissors lift in close proximity to ammonia refrigeration equipment during construction and maintenance activities including, but not limited to, installation of equipment in the Ammonia Machine Room.
Recent events (3)
  • — F (S) $12278
  • — C (S) $12278
  • — Z (S) $12278

1910.119 H02 I

Deleted Serious Gravity 5 1 instance 9 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $12,278 · Current $0 Reduced
29 CFR 1910.119(h)(2)(i):  Employer, when selecting a contractor, did not obtain and evaluate information regarding the contract employer's safety performance and program:  Establishment:  Employer did not evaluate information regarding safety performance and programs for contract employers who perform work on or adjacent to anhydrous ammonia refrigeration equipment.
Recent events (3)
  • — F (S) $0
  • — C (S) $12278
  • — Z (S) $12278

1910.119 H02 II

Deleted Serious Gravity 10 1 instance 9 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR 1910.119(h)(2)(ii):  Employer did not inform contract employers of the known potential fire, explosion, or toxic release hazards related to the contractor's work and the process:  Establishment:  Employer did not inform contract employers of the known potential fire, explosion, or toxic release hazards related to the contractor's work and the process for contractors who work on or adjacent to anhydrous ammonia refrigeration equipment.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.119 H02 III

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR 1910.119(h)(2)(iii):  Employer did not explain to contract employers the applicable provisions of the emergency action plan required by 29 CFR 1910.119(n):  Establishment:  Employer did not explain to contract employers who work on or adjacent to anhydrous ammonia refrigeration equipment the applicable provisions of the emergency action plan required by 29 CFR 1910.119(n).
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.119 H02 IV

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR 1910.119(h)(2)(iv):  Employer did not develop and implement safe work practices consistent with paragraph (f)(4) of this section, to control the entrance, presence and exit of contract employers and contract employees in the covered process areas.  Establishment:  Employer did not develop and implement safe work practices consistent with paragraph (f)(4) of this section, and to control the entrance, presence and exit of contract employees who perform work on or adjacent to anhydrous ammonia refrigeration equipment.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.119 H02 V

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $15,625 · Current $15,625
29 CFR 1910.119(h)(2)(v):  The employer did not periodically evaluate the performance of contract employers to ensure they are fulfilling their obligations as specified in 29 CFR 1910.119(h)(3).  Establishment:  Employer did not periodically evaluate the performance of contract employers including, but not limited to, Brouillette HVAC and Sheetmetal Inc. to ensure they are fulfilling their obligations to train their employees on topics including, but not limited to, work practices necessary to safely perform his/her work on or adjacent to anhydrous ammonia refrigeration equipment.
Recent events (3)
  • — F (S) $15625
  • — C (S) $15625
  • — Z (S) $15625

1910.119 J04 II

Serious Gravity 10 7 instances 410 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $15,625 · Current $15,625
29 CFR  1910.119(j)(4)(ii): Inspection and testing did not follow recognized and generally accepted good engineering practices:   Ammonia Machine Room:  Employer did not follow recognized and generally accepted good engineering practices for inspection and testing of ammonia refrigeration equipment including, but not limited to:  a) Verification of function of the emergency exhaust ventilation system. b) Verification of function of ammonia detection system. c) Tests of functionality of emergency shutdown of ammonia equipment such as compressors, pumps, liquid solenoid valves. d) Tests of functionality of the power failure trouble signal to a monitored location for a power loss to the ammonia detection system. e) Tests of the functionality of emergency ventilation systems alerts to a monitored location upon loss of power or failure. f) Tests of functionality of the safety alarm indicators and safety system software of the computer control system. g) Inspections that verify automatic function of the temperature control ventilation.
Recent events (3)
  • — F (S) $15625
  • — C (S) $15625
  • — Z (S) $15625

1910.119 J04 III

Deleted Serious Gravity 10 2 instances 203 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment to maintain its mechanical integrity, was not consistent with applicable manufacturer's recommendations and good engineering practices, or more frequently determined to be necessary by prior operating experience.     Ammonia Machine (Engine) Room:  Employer did not ensure that the frequency of inspections and tests of the following components/equipment of the ammonia refrigeration system was consistent with applicable manufacturer's recommendations and good engineering practices:  a) The sensors for the ammonia detection system were not calibrated semi-annually as per manufacturer's recommendations,  Home Market Food's mechanical integrity inspection/test schedule, and in accordance with ANSI/IIAR (American National Safety Institute/International Institute of Ammonia Refrigeration) IIAR 6 2019 edition, Table 12.3.  b) Emergency ventilation  for the ammonia machine room was not tested semi-annually  in accordance with ANSI/IIAR (American National Safety Institute/International Institute of Ammonia Refrigeration) IIAR 2 2014 edition, Section 6.14 in the absence of the manufacturer's recommendations for schedule of maintenance.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.119 J06 II

Deleted Serious Gravity 5 1 instance 410 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $12,278 · Current $0 Reduced
29 CFR  1910.119(j)(6)(ii):The employer did not ensure appropriate checks and inspections were performed to assure that equipment was installed properly and consistent with design specifications and the manufacturer's instructions.  Ammonia Machine Room:  On or about December 19, 2022, a release of approximately 21,000 pounds of anhydrous ammonia refrigerant occurred while employees were working inside the ammonia machine room (AMR). Employer did not ensure appropriate checks and inspections were performed to assure that the safety system equipment for the anhydrous ammonia refrigeration system was installed properly and consistent with design specifications:  a) Emergency ventilation equipment in the AMR did not automatically activate when ammonia levels exceeded 150 parts per million (one half the Immediately Dangerous to Life and Health).   b) The alarm for the ammonia leak detection system did not initially activate when the ammonia levels exceeded 25 parts per million (ppm) to alert employees to evacuate.
Recent events (3)
  • — F (S) $0
  • — C (S) $12278
  • — Z (S) $12278

1910.119 L01

Deleted Serious Gravity 10 1 instance 410 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.119(l)(1):  Employer did not implement procedures to manage changes to process chemicals, technology, equipment, and procedures, and changes to facilities that affect a covered process:  Establishment:  Employer upgraded the anhydrous ammonia refrigeration system and did not perform an adequate management of change to the heating system for the ammonia refrigeration equipment in the ammonia machine room.
Recent events (3)
  • — F (S) $0
  • — C (S) $15625
  • — Z (S) $15625

1910.119 L03

Deleted Serious Gravity 5 1 instance 7 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $12,278 · Current $0 Reduced
29 CFR 1910.119(l)(3): Employees involved in operating a process and maintenance and contract employees whose job tasks would be affected by a change in the process were not informed of and trained in the change prior to start-up of the process or affected part of the process.  Ammonia Machine Room:  Employees who operate, monitor, perform maintenance/repairs, and/or perform critical equipment shutdown of ammonia refrigeration system were not informed of and trained in the change prior to start-up of  the upgraded heating system in the Ammonia Machine Room.
Recent events (3)
  • — F (S) $0
  • — C (S) $12278
  • — Z (S) $12278

1910.119 L05

Deleted Serious Gravity 5 1 instance 410 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $12,278 · Current $0 Reduced
29 CFR 1910.119(l)(5):  A change covered by this paragraph resulted in a change in the operating procedures or practices required by paragraph (f) of this section, and such procedures or practices were not updated accordingly:  Establishment:  Employer did not update operating  procedures and practices for the upgraded heating system in the Ammonia Machine Room.
Recent events (3)
  • — F (S) $0
  • — C (S) $12278
  • — Z (S) $12278

1910.119 M05

Deleted Serious Gravity 5 3 instances 6 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $12,278 · Current $0 Reduced
29 CFR 1910.119(m)(5):   Employer did not establish a system to promptly address and resolve the incident report findings and recommendations. Resolutions and corrective actions were not documented.   Establishment:  Employer did not establish a system to promptly address and resolve incident report findings as required by this section for incidents including, but not limited to:  a) On or about August 1, 2022, when a pipe on Compressor AMCOMP 3 broke causing an anhydrous ammonia leak. b) On or about May 17, 2022, approximately 1,000 pounds of anhydrous ammonia was released from the relief valves into the header into the atmosphere.
Recent events (3)
  • — F (S) $0
  • — C (S) $12278
  • — Z (S) $12278

1910.119 M06

Deleted Serious Gravity 5 2 instances 203 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $12,278 · Current $0 Reduced
29 CFR 1910.119(m)(6):  The incident investigation report was not reviewed with all affected personnel whose job tasks are relevant to the incident findings including contract employees where applicable:  Establishment:  Employer did not review the information in the  incident investigation report with affected personnel including, but not limited to, employees who monitor and/or operate the ammonia refrigeration system following the investigation of the incidents:  a) On or about August 1, 2022, when a pipe connection on Compressor REF-AMCOMP 3 broke causing an anhydrous ammonia leak. b) On or about May 17, 2022, approximately 1,000 pounds of anhydrous ammonia was released from the relief valves into the header to the atmosphere.
Recent events (3)
  • — F (S) $0
  • — C (S) $12278
  • — Z (S) $12278

1910.38 C03

Serious Gravity 5 1 instance 20 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $12,278 · Current $12,278
1910.38(c)(3) Procedures to be followed by employees who remain to operate critical plant operations before they evacuate;  Establishment:  On or about December 19, 2022, the employer's emergency response plan for emergencies  involving employees who respond to investigate and or troubleshoot ammonia  releases did not adequately address the following minimum requirements of this standard including, but not limited to, 1910.120(q)(2)(vii) "Decontamination", 1910.120(q)(2)(ix) "Emergency alerting and response procedures" , 1910.120(q)(2)(x) "Critique of response and follow-up" and 1910.120(q)(2)(xi) "PPE and emergency equipment".  Or in the Alternative:  29 CFR 1910.38(c)(3): The emergency action plan did not include the procedures to be followed by employees who remain to operate critical plant operations before they evacuate:  On or about December 19, 2022, the emergency action plan did not include adequate procedures to be followed by employees who remain to operate critical plant operations before they evacuate in that the plan did not specify how employees would evaluate the ammonia levels in their workplace and be provided with appropriate personal protective equipment such as respirators.
Recent events (5)
  • — P (S) $12278
  • — P (S) $12278
  • — F (S) $12278

1910.120 Q06 II

Deleted Serious Gravity 5 1 instance 20 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $12,278 · Current $0 Reduced
29 CFR  1910.120(q)(6)(ii):  First responders at the operational level did not receive at least eight hours of training or did not have sufficient experience to objectively demonstrate competency in the areas required by 29 CFR 1910.120(q)(6)(ii)(A) through (q)(6)(ii)(F) and/or the employer did not so certify:  Establishment:  On or about December 19, 2022, the employer did not ensure that employees who remained to handle critical equipment shutdown, stop any unnecessary equipment or processes during an ammonia leak were not provided training that adequately addressed elements including, but not limited to, the monitoring of ammonia exposure levels, the selection and use of personal protective equipment, and the basic control, containment and confinement operations or decontamination of hazardous materials that may be encountered in an emergency response.
Recent events (3)
  • — F (S) $0
  • — C (S) $12278
  • — Z (S) $12278

1910.151 C

Serious Gravity 1 1 instance 8 exposed
Issued
Jun 16, 2023
Penalty
Initial $7,366 · Current $12,991
29 CFR  1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   Ammonia Machine Room:  On or about December 19, 2022, emergency shower head was rotated upward and, therefore, was not available for immediate use to employees who were working the machine room and were exposed to anhydrous ammonia refrigerant.
Recent events (3)
  • — F (S) $12991
  • — C (S) $7366
  • — Z (S) $7366

1910.165 B01

Serious Gravity 5 1 instance 203 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $12,278 · Current $12,278
29 CFR  1910.165(b)(1): The employee alarm system shall provide warning for necessary emergency action as called for in the emergency action plan, or for reaction time for safe escape of employees from the workplace or the immediate work area, or both:  Establishment:  On or about December 19, 2022, the local emergency alarm system to notify employee(s) of present hazard and to evacuate in that the ammonia alarm system did not automatically activate when there was a significant release of ammonia.
Recent events (3)
  • — F (S) $12278
  • — C (S) $12278
  • — Z (S) $12278

1910.119 D03 I E

Other-than-serious 1 instance 410 exposed
Issued
Jun 16, 2023
Abate by
Aug 8, 2023
Penalty
Initial $1,378 · Current $11,378
29 CFR 1910.119(d)(3)(i)(E): Information pertaining to the equipment in the process did not include a ventilation system design.  Ammonia Machine Room:  Employer did not complete the compilation of information including, but not limited to, the design of the ventilation system for the Ammonia Machine Room.
Recent events (3)
  • — F (O) $11378
  • — C (O) $1378
  • — Z (O) $1378

View Home Market Foods, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346407141.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.