WASHINGTON, PA —
OSHA Inspection: ADVANCED COIL INDUSTRY
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of ADVANCED COIL INDUSTRY in 175 PLUMPTON AVENUE, WASHINGTON, PA 15301 (NAICS 333519). OSHA activity number 346450554.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED COIL INDUSTRY
- Site address
- 175 PLUMPTON AVENUE
- City
- WASHINGTON
- State
- PA
- ZIP
- 15301
- Mailing
- 175 PLUMPTON AVENUE, WASHINGTON, PA 15301
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333519
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.179 L03 I
- Issued
- Apr 20, 2023
- Abate by
- May 16, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(l)(3)(i):Unsafe condition(s) disclosed during the frequent or periodic inspection(s) required by 29 CFR 1910.179(j) were not corrected before operation of the crane(s) was resumed: (a) Facility, Main Bay: On or about January 17, 2023 the company did not repair/replace major mechanical problems with the Trambeam 20 ton overhead crane after an annual inspection inspection of the crane had occurred on July 25, 2022. The items that were not fixed on the 20 ton overhead Trambeam 20 ton crane at the time of the OSHA inspection on January 17, 2023 are as follows: *Bridge guide rollers were heavily worn and need to be replaced (16 per side of the crane). *Guide rollers are heavily worn and need to be replaced. *An oil leak on the trolley drive. *Missing connection box cover on the hoist motor. *Broken wires on wire rope. The wire hoist rope needs replaced. *The outer south side of the lower block sheave is rope drawn and need to be replaced. *The festoon cable needs to be repaired or replaced. *The bridge indicating light is inoperable.
Recent events (1)
- — Z (S) $0
1910.147 C04 I
- Issued
- Apr 20, 2023
- Abate by
- May 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Facility: On or about January 17, 2023, the employer failed to develop an energy control procedures for equipment that employees are required to conduct service and maintenance activities on such as but not limited to the "Wide Face Finishing Machine". The Advanced Coil Industry, was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CRF1910.147(c)(4)(i), which was contained in OSHA inspection number 1608572, citation number 1, item number 1a and was affirmed as a final order on 10/7/2022, with respect to a workplace located at 175 Plimpton Avenue, Washington, PA.
Recent events (1)
- — Z (R) $0
1910.147 C07 I
- Issued
- Apr 20, 2023
- Abate by
- May 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i):The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) Facility: On or about January 17, 2023, the employer did not provide training to employees conducting maintenance and servicing activities that required equipment to be locked and tagged out. The Advanced Coil Industry was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.147(c)(7)(i), which was contained in OSHA inspection number 1608572, citation number 1, item number 1b and was affirmed as a final order on 10/7/2022, with respect to a workplace located at 175 Plimpton Avenue, Washington, PA.
Recent events (1)
- — Z (R) $0
1910.147 D04 I
- Issued
- Apr 20, 2023
- Abate by
- May 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Facility: On or about January 17, 2023, employees would service machinery but did not isolate all energy sources by locking and/or tagging out each energy source. The Advanced Coil Industry was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR1910.147(d)(4)(i), which was contained in OSHA inspection number 1608572, citation number 1, item number 1c and was affirmed as a final order on October 7, 2022, with respect to a workplace located at 175 Plimpton Avenue, Washington, PA.
Recent events (1)
- — Z (R) $0
1910.179 J02 III
- Issued
- Apr 20, 2023
- Abate by
- May 9, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with signed reports, were not performed: (a) Facility: On or about January 17, 2023, monthly inspections of hooks were not performed with a signed report of the inspection. The Advanced Coil Industry was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR1910.179(j)(2)(iii), which was contained in OSHA inspection number 1608572, citation number 1 item number 3b and was affirmed as a final order on October 10, 2022, with respect to a workplace located at 175 Plimpton Avenue, Washington, PA.
Recent events (1)
- — Z (R) $0
More inspections at Advanced Coil Industry