OSHA Inspection: D & S WELDING, LLC

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of D & S WELDING, LLC in 48227 249TH STREET, SHERMAN, SD 57030 (NAICS 333992). OSHA activity number 346475684.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D & S Welding, LLC — free Get an email when a new federal OSHA severe-injury report for D & S Welding, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
D & S WELDING, LLC
Site address
48227 249TH STREET
City
SHERMAN
State
SD
ZIP
57030
Mailing
48227 249TH STREET, SHERMAN, SD 57030
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333992
Employees
18
Ownership type
A

4 citations on file for this inspection.

1910.305 G02 III

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 13, 2023
Abate by
Aug 8, 2023
Penalty
Initial $2,946 · Current $2,063 Reduced
29 CFR  1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   (a)D & S Welding, LLC at  48277 249th Street, Sherman, SD 57030:  On or about and at times prior to February 1, 2023, the employer did not ensure that electrical equipment was free from damage in that the electrical cord on the quick disconnect of the Piranha Ironworker was separating from the plug and exposed the inner connectors.  This condition exposed employees to shock hazards.
Recent events (2)
  • — I (S) $2062.6
  • — Z (S) $2946

1910.253 B02 II

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 13, 2023
Abate by
Aug 8, 2023
Penalty
Initial $5,892 · Current $4,124 Reduced
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:  (a)D & S Welding, LLC at 48277 249th Street, Sherman, SD 57030:  On or about and at times prior to February 1, 2023, the employer did not ensure the Argon/Carbon Dioxide welding tanks were protected from damage or being knocked over.  Tanks were being stored chained together but were not secured to a wall or stored in an enclosure.  This condition exposed employees to potential struck-by hazards associated with the unsecure pressurized tanks.  D & S Welding, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.253(b)(2)(ii), which was contained in OSHA inspection number 1609792, citation number 1, item number 5 and was affirmed as a final order on November 18, 2022, with respect to a workplace located at 48277 249th Street, Sherman, SD 57030.
Recent events (2)
  • — I (S) $4124.4
  • — Z (R) $5892

1910.134 H02 I

Other-than-serious 1 instance 7 exposed
Issued
Jul 13, 2023
Abate by
Aug 8, 2023
Penalty
Initial $551 · Current $386 Reduced
29 CFR  1910.134(h)(2)(i): All respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals, and they were not packed or stored to prevent deformation of the facepiece and exhalation valve:  (a)D & S Welding, LLC at 48277 249th Street, Sherman, SD 57030:  On or about and at times prior to February 1, 2023, the employer did not ensure that respirators were stored and maintained properly or in accordance with the manufacturer's recommendations.  This condition exposed employees to health hazards associated with improper storage, loss of fit due to respirator deformation, and contamination.
Recent events (2)
  • — I (O) $385.7
  • — Z (O) $551

1910.1200 F06

Other-than-serious 1 instance 18 exposed
Issued
Jul 13, 2023
Abate by
Aug 8, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled:   (a)D & S Welding, LLC at  48277 249th Street, Sherman, SD 57030:  On or about and at times prior to February 1, 2023, the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked in that an unlabeled roller lubricant was being used to lubricate the feeder rollers within the facility.  This condition exposed employees to hazards associated with ingestion, inhalation or absorption of hazardous chemicals.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View D & S Welding, LLC's full OSHA safety record →