OSHA Inspection: ERNEST P. BREAUX ELECTRICAL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ERNEST P. BREAUX ELECTRICAL, INC. in ENGINEERING LANE AND STADIUM DR., BATON ROUGE, LA 70816 (NAICS 238210). OSHA activity number 346484355.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ernest P. Breaux Electrical, INC. — free Get an email when a new federal OSHA severe-injury report for Ernest P. Breaux Electrical, INC. is published. One employer, no account, unsubscribe in one click.
Site address
ENGINEERING LANE AND STADIUM DR.
City
BATON ROUGE
State
LA
ZIP
70816
Mailing
2812 BROKEN ARROW ROAD, NEW IBERIA, LA 70560
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.404 F06

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Feb 13, 2023
Penalty
Initial $7,813 · Current $0 Reduced
29 CFR  1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous.   On or about February 6, 2023, employees were using a "sump pump" to remove access water from an excavation that power cord was missing a grounding pin and the pump was not double insulated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7813

1926.651 G01 I

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Feb 13, 2023
Abate by
Feb 27, 2023
Penalty
Initial $10,938 · Current $8,500 Reduced
29 CFR 1926.651(g)(1)(i): Where oxygen deficiency (atmospheres containing less than 19.5 percent oxygen) or a hazardous atmosphere exists or could reasonably be expected to exist, such as in excavations in landfill areas or excavations in areas where hazardous substances are stored nearby, the atmospheres in the excavation shall be tested before employees enter excavations greater than 4 feet (1.22 m) in depth.  On or about February 6, 2023, employees were preparing an excavation for boring tasks in a trench greater than five feet in depth where a possible hazardous atmosphere existed. The atmosphere in the excavation was not tested before allowing employees to enter the excavation.
Recent events (2)
  • — I (O) $8500
  • — Z (S) $10938

1926.652 A01

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Feb 13, 2023
Abate by
Feb 27, 2023
Penalty
Initial $9,376 · Current $9,376
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).   On or about February 6, 2023, employees were preparing an excavation for boring tasks in a trench greater than five feet in depth that was not protected from cave-ins by an adequate protective system.
Recent events (2)
  • — I (O) $9376
  • — Z (S) $9376