Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ERNEST P. BREAUX ELECTRICAL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ERNEST P. BREAUX ELECTRICAL, INC. in S. STADIUM DR. & TOWER DRIVE LSU CAMPUS, BATON ROUGE, LA 70808 (NAICS 238210). OSHA activity number 346694581.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ernest P. Breaux Electrical, INC. — free Get an email when a new federal OSHA severe-injury report for Ernest P. Breaux Electrical, INC. is published. One employer, no account, unsubscribe in one click.
Site address
S. STADIUM DR. & TOWER DRIVE LSU CAMPUS
City
BATON ROUGE
State
LA
ZIP
70808
Mailing
2812 BROKEN ARROW ROAD, NEW IBERIA, LA 70560
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.651 C01 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jun 2, 2023
Penalty
Initial $7,813 · Current $0 Reduced
29 CFR 1926.651(c)(1)(i): Structural ramps used solely by employees as a means of access or egress from excavations were not designed by a competent person:  On or about May 9, 2023, employees were installing a line in excavation 4 feet or more in-depth using a ramp for access or egress not designed by a competent person qualified in structural design.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7813

1926.651 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 2, 2023
Penalty
Initial $10,938 · Current $10,938
29 CFR 1926.651(c)(2): A stairway, ladder, ramp, or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in-depth to require no more than 25 feet (7.62m) of lateral travel for employees.   On or about May 9, 2023, employees were installing a line in excavation 4 feet or more in-depth that did not have a safe means of egress.
Recent events (2)
  • — I (S) $10938
  • — Z (S) $10938

1926.651 C01 V

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Jun 2, 2023
Penalty
Initial $7,813 · Current $7,813
29 CFR 1926.651(c)(1)(v): Structural ramps used in lieu of steps were not provided with cleats or other surface treatments on the top surface to prevent slipping.   On or about May 9, 2023, employees were installing a line in excavation 4 feet or more in-depth using a ramp for access or egress not designed by a competent person qualified in structural design and did not have cleating or other surface treatment to prevent the employees from slipping.
Recent events (2)
  • — I (O) $7813
  • — Z (S) $7813

View Ernest P. Breaux Electrical, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346694581.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.