PHOENIX, AZ —
OSHA Inspection: INDIAN HEALTH SERVICE/PHOENIX INDIAN MEDICAL CENTER (PIMC)
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of INDIAN HEALTH SERVICE/PHOENIX INDIAN MEDICAL CENTER (PIMC) in 4212 N 16TH STREET, PHOENIX, AZ 85016 (NAICS 622110). OSHA activity number 346488554.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 4212 N 16TH STREET
- City
- PHOENIX
- State
- AZ
- ZIP
- 85016
- Mailing
- ATTENL ENVIRONMENTAL HEALTH AND SAFETY 4212 N 16TH STREET, PHOENIX, AZ 85016
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 622110
- Employees
- 1037
- Ownership type
- D
Citations
2 citations on file for this inspection.
1910.134 H02 I
- Issued
- Feb 15, 2023
- Abate by
- Feb 22, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i):Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: Welding shop: A respirator was not stored to protect it from contamination, exposing the employee to respiratory hazards from inhalation of contaminants.
Recent events (1)
- — Z (S) $0
1910.253 B04 I
- Issued
- Feb 15, 2023
- Abate by
- Feb 22, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(i):Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; a) Central plant: An oxygen cylinder was stored next to 4 acetylene cylinders, exposing employees to burns from explosions.
Recent events (1)
- — Z (S) $0
More inspections at Indian Health Service/Phoenix Indian Medical Center (Pimc)
View Indian Health Service/Phoenix Indian Medical Center (Pimc)'s full OSHA safety record →