WESTMONT, IL —
OSHA Inspection: UNO CONSTRUCTION CO.,INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UNO CONSTRUCTION CO.,INC. in 2 N. WILLIMAS, WESTMONT, IL 60559 (NAICS 237110). OSHA activity number 346497274.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNO CONSTRUCTION CO.,INC.
- Site address
- 2 N. WILLIMAS
- City
- WESTMONT
- State
- IL
- ZIP
- 60559
- Mailing
- 6037 BROOKBANK ROAD, DOWNERS GROVE, IL 60516
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.651 J02
- Issued
- Mar 31, 2023
- Abate by
- Apr 14, 2023
- Penalty
- Initial $2,679 · Current $1,475 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. On or about February 10, 2023, a spoil pile was placed within two (2) feet from the trench edge, exposing employees in the trench to struck-by hazards. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $1475
- — Z (S) $2679
1926.651 K01
- Issued
- Mar 31, 2023
- Abate by
- Apr 28, 2023
- Penalty
- Initial $4,688 · Current $2,560 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated. On or about February 10, 2023, daily inspections of excavations were not conducted by a competent person, exposing employees to trenching hazards such as struck-by and caught-in. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $2560
- — Z (S) $4688
1926.652 A01
- Issued
- Mar 31, 2023
- Abate by
- Apr 14, 2023
- Penalty
- Initial $4,688 · Current $2,560 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: On or about February 10, 2023, employees were not protected by a protective system while working in a trench at a depth of 7 feet, exposing employees to struck-by hazards associated with a cave-in. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $2560
- — Z (S) $4688
1926.1053 B01
- Issued
- Mar 31, 2023
- Abate by
- Apr 14, 2023
- Penalty
- Initial $2,009 · Current $1,105 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support: On or about February 10, 2023, employees used a portable ladder where the side rails did not extend three feet past the landing of the trench, exposing employees to a fall hazard. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $1105
- — Z (S) $2009
More inspections at UNO Construction Co.,Inc.