Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: US DEPARTMENT OF JUSTICE/FEDERAL BUREAU OF PRISONS- FCI ENGLEWOOD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of US DEPARTMENT OF JUSTICE/FEDERAL BUREAU OF PRISONS- FCI ENGLEWOOD in 9595 W. QUINCY AVE., LITTLETON, CO 80123 (NAICS 922140). OSHA activity number 346499924.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch US Department of Justice/Federal Bureau of Prisons- FCI Englewood — free Get an email when a new federal OSHA severe-injury report for US Department of Justice/Federal Bureau of Prisons- FCI Englewood is published. One employer, no account, unsubscribe in one click.
Site address
9595 W. QUINCY AVE.
City
LITTLETON
State
CO
ZIP
80123
Mailing
9595 W. QUINCY AVE., LITTLETON, CO 80123
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922140
Employees
1000
Ownership type
D

5 citations on file for this inspection.

1910.213 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 6, 2023
Abate by
May 23, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  (a) On or before 2/10/23, the employer did not ensure that the DeWalt jobsite table saw was equipped with its hood guard as required by this standard. The DeWalt jobsite table saw lacked its hood guard. This condition exposed employees to amputation and kickback hazards.
Recent events (1)
  • — Z (S) $0

1910.213 C03

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 6, 2023
Abate by
May 23, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:  (a) On or before 2/10/23, the employer did not ensure that the DeWalt table saw was used with all required safety equipment when used to cut plywood. The table saw lacked non-kickback fingers. This condition exposed employees to kickback hazards.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 6, 2023
Abate by
May 23, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  (a) On or before 2/10/23, the employer did not ensure that the Skil bench grinder had its work rest adjusted to no more than 1/8" away from the grinding wheel. This condition exposed employees to ingoing nip hazards as well as flying chips and sparks.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 6, 2023
Abate by
May 23, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) On or before 2/10/23, the employer did not protect employees from injury in that the gap between the tongue guard and the grinding wheel on the Skil bench grinder exceeded 1/4 of an inch. This condition exposed employees to flying chip and sparks.
Recent events (1)
  • — Z (S) $0

1910.303 G01 II

Other-than-serious 1 instance 15 exposed
Issued
Apr 6, 2023
Abate by
May 23, 2023
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  (a) On or before 2/10/23, the employer did not ensure that the service panel in the kitchen area had at least 30 inches of clearance. In the kitchen near the coolers, pallet jacks were stored within 30 inches of the service panel. This condition exposed employees to electric shock and fire hazards.  (b) On or before 2/10/23, the employer did not ensure that the service panel in the wood shop building had at least 30 inches of clearance. Miscellaneous items were stored within 30 inches of the panel. This condition exposed employees to electric shock and fire hazards.
Recent events (1)
  • — Z (O) $0

View US Department of Justice/Federal Bureau of Prisons- FCI Englewood's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346499924.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.