CHAMPIONS GATE, FL —
OSHA Inspection: JACOB STUCCO LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JACOB STUCCO LLC in 1299 SOUTH GOODMAN ROAD, CHAMPIONS GATE, FL 33896 (NAICS 238140). OSHA activity number 346526411.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JACOB STUCCO LLC
- Site address
- 1299 SOUTH GOODMAN ROAD
- City
- CHAMPIONS GATE
- State
- FL
- ZIP
- 33896
- Mailing
- 618 SAN JUAN BLVD, ORLANDO, FL 32807
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01 I
- Issued
- May 16, 2023
- Abate by
- May 26, 2023
- Penalty
- Initial $2,679 · Current $2,679
General-duty citation text
29 CFR 1926.451(b)(1)(i):Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. (a) On or about February 23, 2023, at 1299 South Goodman Road, Champions Gate, FL: employees were exposed to fall hazards of approximately 6 feet 6 inches in that the spacing in between the individual walk planks and the spacing between the platform and the uprights was approximately 2.5 inches.
Recent events (1)
- — Z (S) $2679
1926.451 B04
- Issued
- May 16, 2023
- Abate by
- May 26, 2023
- Penalty
- Initial $2,679 · Current $2,679
General-duty citation text
29 CFR 1926.451(b)(4): Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm) (a) On or about February 23, 2023, at 1299 South Goodman Road, Champions Gate, FL. employees were exposed to fall hazards in that individual walk planks extended approximately 4.5 inches over the center line of its support and were not cleated or otherwise restrained.
Recent events (1)
- — Z (S) $2679
1926.451 G04 VII
- Issued
- May 16, 2023
- Abate by
- Jun 12, 2023
- Penalty
- Initial $3,349 · Current $3,349
General-duty citation text
29 CFR 1926.451(g)(4)(vii):Each toprail or equivalent member of a guardrail system was not capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along its top edge of at least 100 pounds (445 n) or guardrail systems installed on single-point adjustable suspension scaffolds or two-point adjustable suspension scaffolds, and at least 200 pounds (890 n) for guardrail systems installed on all other scaffolds. (a) On or about February 23, 2023, at 1299 South Goodman Road, Champions Gate, FL. employees were exposed to fall hazards of approximately 13 feet 3 inches in that the scaffold guardrail system was erected in such a way that it was not capable of supporting at least 200 pounds.
Recent events (1)
- — Z (S) $3349
1926.454 A
- Issued
- May 16, 2023
- Abate by
- Jul 5, 2023
- Penalty
- Initial $9,375 · Current $9,375
General-duty citation text
29 CFR 1926.454(a):The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) On or about February 23, 2023, at 1299 South Goodman Road, Champions Gate, FL: employees were exposed to fall hazards of approximately 13 feet 3 inches while working from a scaffold, in that they were not trained in the hazards associated with working from a scaffold system. Jacob Stucco LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.454(a) which was contained in OSHA inspection number 1496184, citation number 1, item number 2 and was affirmed as a final order on 04/12/2021, with respect to a workplace located at 600 E. Bay Street, Building A3, Lakeland, Florida 33801.
Recent events (1)
- — Z (R) $9375
More inspections at Jacob Stucco LLC
View Jacob Stucco LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346526411.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.