Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DIXIE PRECAST, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DIXIE PRECAST, INC. in 2950 ANGELLETTE DRIVE, AUSTELL, GA 30106 (NAICS 327390). OSHA activity number 346535057.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dixie Precast, INC. — free Get an email when a new federal OSHA severe-injury report for Dixie Precast, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DIXIE PRECAST, INC.
Site address
2950 ANGELLETTE DRIVE
City
AUSTELL
State
GA
ZIP
30106
Mailing
2950 ANGELLETTE DRIVE, AUSTELL, GA 30106
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
12
Ownership type
A

6 citations on file for this inspection.

1910.215 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 21, 2023
Abate by
Sep 19, 2023
Penalty
Initial $3,572 · Current $3,572
29 CFR  1910.215(a)(1):Abrasive wheel(s) used on grinding machinery were not used with safety guard(s):  a) Outdoor Work Area: On or about March 1, 2023, and at times prior, the employer exposed employees to struck-by hazards, in that the Makita angle grinder used to grind concrete was fitted with an unguarded abrasive wheel.
Recent events (2)
  • — I (S) $3572
  • — Z (S) $3572

1910.303 B01

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 21, 2023
Abate by
Sep 19, 2023
Penalty
Initial $2,678 · Current $2,678
29 CFR  1910.303(b)(1):Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  a) Employee Restroom: On or about March 1, 2023, and at times prior, the employer exposed employees to electrical shock and fire hazards, in that the flexible cable powering the restroom's water heater was not maintained free of damage, including exposed wiring.
Recent events (2)
  • — I (S) $2678
  • — Z (S) $2678

1910.304 G05

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 21, 2023
Abate by
Sep 19, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.304(g)(5):The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a) Employee Restroom: On or about March 1, 2023, the employer exposed employees to electrical shock or fire hazards, in that the ground pin for the compact electric water heater in the restroom was missing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 2 instances 1 exposed
Issued
Aug 21, 2023
Abate by
Sep 19, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(2)(iii):Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a) Outdoor Work Area: On or about March 1, 2023, the employer exposed employees to electrical shock and fire hazards, in that strain relief was not maintained for the flexible cable powering the Makita angle grinder at the point where the cable meets the equipment body.  b) Outdoor Work Area: On or about March 1, 2023, the employer exposed employees to electrical shock and fire hazards, in that strain relief was not maintained for the extension cord providing power to the Makita angle grinder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 21, 2023
Abate by
Sep 19, 2023
Penalty
Initial $2,678 · Current $2,678
29 CFR  1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) Production Area, Foreman's Office Space: On March 1, 2023, and at times prior, the employer exposed employees to electrical shock and fire hazards, in that the foreman's office area was located directly beside and in front of two electrical panels. Office furniture and equipment obstructed access to the panels.
Recent events (2)
  • — I (S) $2678
  • — Z (S) $2678

1910.178 L06

Other-than-serious 1 instance 2 exposed
Issued
Aug 21, 2023
Abate by
Sep 19, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(6):The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  a) Loading Dock: On or about March 1, 2023, and at times prior, the employer exposed employees to struck-by hazards in that the employer did not document that each forklift operator has been successfully trained and evaluated.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Dixie Precast, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346535057.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.