Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADV MASONRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADV MASONRY, INC. in CHICAGO & LOOMIS SOUTHEAST CORNER, NAPERVILLE, IL 60540 (NAICS 238140). OSHA activity number 346563711.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ADV Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for ADV Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ADV MASONRY, INC.
Site address
CHICAGO & LOOMIS SOUTHEAST CORNER
City
NAPERVILLE
State
IL
ZIP
60540
Mailing
400 N. SCHMIDT #-210, BOLINGBROOK, IL 60440
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 21, 2023
Abate by
May 5, 2023
Penalty
Initial $3,349 · Current $1,750 Reduced
29 CFR  1926.451(b)(1):Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:  On or about March 14, 2023, the working section of scaffold was not fully planked between the uprights, exposing employees to a fall of over 25 feet.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3349

1926.451 C01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 21, 2023
Abate by
May 5, 2023
Penalty
Initial $3,349 · Current $1,750 Reduced
29 CFR  1926.451(c)(1)(ii):Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).  On or about March 14, 2023, scaffold guys/ ties were not installed at the closest 4:1 height or less, exposing employees to a possible scaffold collapse.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3349

1926.451 F07

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 21, 2023
Abate by
May 19, 2023
Penalty
Initial $4,688 · Current $2,500 Reduced
29 CFR  1926.451(f)(7):Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.  On or about March 14, 2023, employees erected and worked from a scaffold without the supervision of a competent person, exposing employees to falls and a possible scaffold collapse.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4688

1910.178 L01 II

Other-than-serious 1 instance 3 exposed
Issued
Apr 21, 2023
Abate by
May 19, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.178(l)(1)(ii):Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).  On or about March 14, 2023, an employee was allowed to operate a rough terrain forklift prior to the employer ensuring the employee's training was completed and valid, exposing employees to struck-by hazards.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ADV Masonry, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346563711.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.