Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GALION, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GALION, LLC in 515 N. EAST ST., GALION, OH 44833 (NAICS 332710). OSHA activity number 346614845.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Galion, LLC — free Get an email when a new federal OSHA severe-injury report for Galion, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
GALION, LLC
Site address
515 N. EAST ST.
City
GALION
State
OH
ZIP
44833
Mailing
515 N. EAST ST., GALION, OH 44833
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
130
Ownership type
A

7 citations on file for this inspection.

1910.95 C01

Serious Gravity 10 3 instances 10 exposed
Issued
Jun 29, 2023
Abate by
Jul 18, 2023
Penalty
Initial $15,625 · Current $10,000 Reduced

Hazardous substances 8110

29 CFR  1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8-hour Time-Weighted Average (TWA) sound level of 85 dBA:   Galion, LLC located at 515 N. East Street in Galion, Ohio: On or about June 13, 2023, employees working within the ACME room were exposed to noise greater than 90 decibels. Failure to implement an effective hearing conservation program for employees whose exposures are greater than 85 decibels, exposes employees to Standard Threshold Shifts, chronic hearing loss, and other irreversible audiometric conditions.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $15625

1910.95 K01

Serious Gravity 10 3 instances 10 exposed
Issued
Jun 29, 2023
Abate by
Jul 18, 2023
Penalty
Initial $15,625 · Current $0 Reduced

Hazardous substances 8111

29 CFR  1910.95(k)(1):The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k):  Galion, LLC located at 515 N. East Street in Galion, Ohio: On or about June 13, 2023, employees working within the AMCE room were exposed to noise greater than 85 decibels measured on a 8-hour Time Weighted Average. Failure to ensure employees trained on the hazards associated with hazardous noise and participate with the hearing conservation program can contribute to chronic hearing loss, Standard Threshold Shifts, and other irreversible noise-related illnesses.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

1910.178 F02

Serious Gravity 1 2 instances 2 exposed
Issued
Jun 29, 2023
Penalty
Initial $6,696 · Current $10,000
29 CFR  1910.178(f)(2):The storage and handling of liquefied petroleum gas fuel was not in accordance with NFPA Storage and Handling of Liquefied Petroleum Gases (NFPA No. 58-1969), which is incorporated by reference as specified in Sec. 1910.6:  Galion, LLC located at 515 N. East Street in Galion, Ohio:  On or about April 6, 2023, employees working within the maintenance bay were exposed liquified petroleum gas tanks that were not properly stored. The liquified petroleum gas tanks were removed from powered industrial vehicles which were being serviced by the maintenance technician. Failure to safely store liquefied petroleum gas tanks exposes employees to potential fire and/or explosion hazards.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $6696

1910.178 L01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 29, 2023
Abate by
Jul 18, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  Galion, LLC located at 515 N. East Street in Galion, Ohio: On or about February 14, 2023, the employer did not ensure that each operator was competent to operate powered industrial vehicles demonstrated through successful completion of training and evaluation requirements. Failure to ensure employees are competent to operate powered industrial vehicles exposed an employee to struck-by hazards while operating the PIV near the CNC room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

1910.178 Q01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 29, 2023
Penalty
Initial $11,162 · Current $0 Reduced
29 CFR  1910.178(q)(1):Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:  Galion, LLC located at 515 N. East Street in Galion, Ohio: On or about April 6, 2023, the employer did not ensure that powered industrial vehicle that is not in a safe operating condition was removed from service. Powered industrial vehicle Yale #G7 (S/n E187V21263A) was observed to have damaged hydraulic lines. Failure to remove PIVs that are in a disrepair condition exposes employees to crushed-by or struck-by injuries in the event of a hydraulic system failure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11162

1910.253 E06 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 29, 2023
Penalty
Initial $11,162 · Current $10,000 Reduced
29 CFR  1910.253(e)(6)(ii): Where regulators or parts of regulators, including gages, need repair, the repair should be made by a qualified person.  Galion, LLC located at 515 N. East Street in Galion, Ohio: On or about April 6, 2023, the employer did not ensure that regulators on the oxygen-acetylene torches in need of repair were removed from service and repaired by a qualified person. The oxygen-acetylene torches located in the maintenance bay were discovered to have defective regulators, in that the gauge lens was broken. Failure to ensure regulators in need of repair were repaired by a qualified person exposes employees to potential fire and explosion hazards during use of the equipment.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $11162

1910.303 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 29, 2023
Penalty
Initial $11,162 · Current $0 Reduced
29 CFR  1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:   Galion, LLC located at 515 N. East Street in Galion, Ohio: On or about April 6, 2023, the employer did not ensure that the damaged electrical box used to power the ESAB EMP 215ic was free from recognized hazards likely to cause death or serious harm to employees. Employees within the maintenance bay utilized a metal junction box affixed to a flexible cord as part of the power supply for the ESAB EMP 215ic welder. Failure to remove damaged electrical equipment from service exposed employees to electrical shock and burn hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11162

View Galion, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346614845.