Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALFAB, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALFAB, INC. in 220 BOLL WEEVIL CIRCLE EAST, ENTERPRISE, AL 36331 (NAICS 332323). OSHA activity number 346633043.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alfab, INC. — free Get an email when a new federal OSHA severe-injury report for Alfab, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ALFAB, INC.
Site address
220 BOLL WEEVIL CIRCLE EAST
City
ENTERPRISE
State
AL
ZIP
36331
Mailing
P.O. BOX 311327, ENTERPRISE, AL 36331
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
85
Ownership type
A

2 citations on file for this inspection.

1910.252 B02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 21, 2023
Abate by
Aug 16, 2023
Penalty
Initial $3,984 · Current $3,984
29 CFR  1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  a) Miscellaneous Line - On or about April 11, 2023, and at times prior thereto, employees who were in the area of the Miscellaneous Line were exposed to arc welding rays due to the lack of welding screens between themselves and the active welders.
Recent events (1)
  • — Z (S) $3984

1910.303 B01 I

Other-than-serious 1 instance 2 exposed
Issued
Jul 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(1)(i): Electrical equipment was not suitable for installation and use in conformity with the provisions of this subpart and not free from recognized hazards that are likely to cause death or serious physical harm to employees.   a) Maintenance Department: On or about April 11, 2023, and at times prior thereto, employees were exposed to electrical shock hazards in that they were allowed to use a job-made extension cord with a steel box enclosure that was intended to be used as a permanent installation.
Recent events (1)
  • — Z (O) $0

View Alfab, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346633043.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.