Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THERMO FISHER SCIENTIFIC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THERMO FISHER SCIENTIFIC in 401 MILL CREEK ROAD BLDG 300, MARIETTA, OH 45750 (NAICS 334516). OSHA activity number 346799935.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Thermo Fisher Scientific — free Get an email when a new federal OSHA severe-injury report for Thermo Fisher Scientific is published. One employer, no account, unsubscribe in one click.
Site address
401 MILL CREEK ROAD BLDG 300
City
MARIETTA
State
OH
ZIP
45750
Mailing
401 MILL CREEK ROAD BLDG 300, MARIETTA, OH 45750
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334516
Employees
431
Ownership type
A

1 citation on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 2, 2023
Abate by
Nov 6, 2023
Penalty
Initial $15,625 · Current $9,375 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.  29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.  a. On or about May 1, 2023, the employer did not ensure that the point of operation on the Amada Press Brake, Asset ID MAR500367, Press Brake #3, was appropriately guarded to protect the operator's hand and/or fingers from being caught in-between the dies while forming a part.
Recent events (2)
  • — I (S) $9375
  • — Z (S) $15625