CRYSTAL LAKE, IL —
OSHA Inspection: MORAN MASONRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MORAN MASONRY, INC. in 111 E CRYSTAL LAKE AVE, CRYSTAL LAKE, IL 60012 (NAICS 238140). OSHA activity number 346873771.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MORAN MASONRY, INC.
- Site address
- 111 E CRYSTAL LAKE AVE
- City
- CRYSTAL LAKE
- State
- IL
- ZIP
- 60012
- Mailing
- 173 LEXINGTON AVE., SOUTH ELGIN, IL 60177
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 E01
- Issued
- Sep 22, 2023
- Penalty
- Initial $6,250 · Current $3,125 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. (a): On or about July 31, 2023, The employer did not ensure that supported scaffolds had a ladder or equivalent method for employees to access the upper work platforms. Employees climbed the crossbraces of the scaffold, exposing them to falls of approximately 10.8 feet to the ground below.
Recent events (2)
- — I (S) $3125
- — Z (S) $6250
1926.451 G01
- Issued
- Sep 22, 2023
- Penalty
- Initial $6,250 · Current $3,125 Reduced
General-duty citation text
29 CFR 1926.451(g)(1):Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. (a): On or about July 31, 2023, The employer did not ensure that supported scaffolds were free of potential fall hazards. Employees operating at approximately 10.8 feet or more above a lower level were not protected from falling to that lower level by fall protection as established in paragraphs (g)(1)(i)-(g)(1)(vii) of this section.
Recent events (2)
- — I (S) $3125
- — Z (S) $6250
1926.451 H01
- Issued
- Sep 22, 2023
- Penalty
- Initial $3,572 · Current $1,786 Reduced
General-duty citation text
29 CFR 1926.451(h)(1): In addition to wearing hardhats each employee on a scaffold shall be provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, or guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. When the falling objects are too large, heavy or massive to be contained or deflected by any of the above-listed measures, the employer shall place such potential falling objects away from the edge of the surface from which they could fall and shall secure those materials as necessary to prevent their falling. (a): On or about July 31, 2023, The employer did not ensure that scaffolds had toeboards installed to contain or deflect tools or equipment from the upper level. Employees operating on a lower level were exposed to struck-by hazards from falling objects.
Recent events (2)
- — I (S) $1786
- — Z (S) $3572
1926.602 D
- Issued
- Sep 22, 2023
- Abate by
- Oct 23, 2023
- Penalty
- Initial $4,465 · Current $2,233 Reduced
General-duty citation text
29 CFR 1926.602(d): Powered industrial truck operator training. Note: The requirements applicable to construction work under this paragraph are identical to those set forth at 1910.178(l) of this chapter. 29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l), with certification records that includes the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation: (a): On or about July 31, 2023, the employer did not certify that forklift operator(s) had been trained and evaluated as required by paragraph (l) with certification records. An employee was operating a JLG forklift to deliver bricks and mortar to the upper level of a scaffold, approximately 10.8 feet above the lower level. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $2233
- — Z (S) $4465
More inspections at Moran Masonry, INC.
View Moran Masonry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346873771.