Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ASC ENGINEERED SOLUTIONS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ASC ENGINEERED SOLUTIONS, LLC in 2751 WEST AVE, ASHTABULA, OH 44004 (NAICS 325212). OSHA activity number 346878002.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ASC Engineered Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for ASC Engineered Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2751 WEST AVE
City
ASHTABULA
State
OH
ZIP
44004
Mailing
2751 WEST AVE, ASHTABULA, OH 44004
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325212
Employees
103
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 26, 2023
Abate by
Nov 22, 2023
Penalty
Initial $11,162 · Current $11,162
29 CFR  1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  On or about August 1, 2023, the employer failed to maintain specific energy control procedures which outlined the intended use; contained specific procedural steps for shutting down, isolating, blocking and securing machines or equipment;  contained specific procedural steps for the placement, removal and transfer of lockout devices and responsibility for those devices; and specific requirements for testing a machine or equipment to determine and verify the effectiveness of the energy control devices or other energy control measures. Employees were exposed to electrical, pneumatic, hydraulic energy sources.
Recent events (2)
  • — I (S) $11162
  • — Z (S) $11162

1910.242 B

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 26, 2023
Abate by
Nov 15, 2023
Penalty
Initial $11,162 · Current $5,581 Reduced
29 CFR  1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  On or about August 1, 2023, the employer failed to ensure that compressed air used for cleaning was reduced below 30 p.s.i. or that the air nozzles had an effective dead-end relief valve.
Recent events (2)
  • — I (S) $5581
  • — Z (S) $11162

1910.335 A01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Oct 26, 2023
Abate by
Nov 15, 2023
Penalty
Initial $11,162 · Current $0 Reduced
29 CFR  1910.335(a)(1): Employees working in areas where there are potential electrical hazards were not provided with, and did not use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed:   On or about August 1, 2023, the employer did not provide electrical protective equipment for employees working in areas with 240 volt to 480 volt energized parts where there was the potential for electrocution, electric shock, and/or arc flash hazards. Employees were not provided with general protective equipment including head protection, eye or face protection, and rubber gloves.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11162

1910.335 A02 I

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Oct 26, 2023
Abate by
Nov 15, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts:   On or about August 1, 2023, the employer did not provide insulated tools or handling equipment for employees working in areas with 240 volt to 480 volt energized parts where there was the potential for contact with conductor parts. Employees were required to work within electrical cabinets and were not provided insulated tools.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View ASC Engineered Solutions, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346878002.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.