Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FERRELLGAS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FERRELLGAS INC. in 1500 NE PINK HILL ROAD, BLUE SPRINGS, MO 64014 (NAICS 454310). OSHA activity number 346982465.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ferrellgas INC. — free Get an email when a new federal OSHA severe-injury report for Ferrellgas INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FERRELLGAS INC.
Site address
1500 NE PINK HILL ROAD
City
BLUE SPRINGS
State
MO
ZIP
64014
Mailing
1775 NORTH CHOUTEAU TRAFFICWAY, KANSAS CITY, MO 64120
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
454310
Employees
25
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 1 instance 19 exposed
Issued
Mar 7, 2024
Abate by
Apr 2, 2024
Penalty
Initial $12,676 · Current $0 Reduced

Hazardous substances 2150

OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:  On or about September 15, 2023, at a worksite located at 1500 NE Pink Hill Road, Blue Springs, MO:  The employer exposed an employee to the recognized fire and explosion hazards associated with leaking propane gas. The employer sent an employee to respond to a report of a gas leak at a customer home. The employee made a repair to a broken gas line that fed propane from the tank outside into the home. The employee then entered the home's basement to light the pilot light on the hot water heater.  As he did so, propane gas accumulated in the basement ignited and exploded, injuring the employee.
Recent events (3)
  • — F (S) $0
  • — C (S) $12676
  • — Z (S) $12676

1910.132 D02

Other-than-serious Gravity 5 1 instance 19 exposed
Issued
Mar 7, 2024
Abate by
Dec 31, 2024
Penalty
Initial $12,676 · Current $25,352

Hazardous substances 2150

1910.132(d)(2)  The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.   At a worksite located at 1500 NE Pink Hill Road, Blue Springs, MO:  Employer did not adequately document its PPE hazard assessment in a manner that explained its good faith determination that FR or cotton-only work clothing was not required for field technicians.
Recent events (3)
  • — F (O) $25352
  • — C (S) $12676
  • — Z (S) $12676

1910.132 D01

Deleted Serious Gravity 5 1 instance 25 exposed
Issued
Mar 7, 2024
Abate by
Apr 2, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 2150

29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  At a worksite located at 1500 NE Pink Hill Road, Blue Springs, MO:  Employees were exposed to fire and explosion hazards. This was last demonstrated on or about September 15, 2023, and at times prior thereto, when workers were engaged in liquid petroleum gas (propane) activities including but not limited to residential properties. The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). Employees responding to calls of service were not provided with and or required to wear clothing which was flame-resistant or made of 100% cotton during the performance of the duties. Employees were exposed to fire and explosion hazards when working with propane gas which can or has the potential to accumulated in the work area(s).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1200 F06 II

Deleted Other-than-serious 1 instance 19 exposed
Issued
Mar 7, 2024
Abate by
Apr 2, 2024
Penalty
Initial $0 · Current $0

Hazardous substances 2150

29 CFR  1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  At a worksite located at 1500 NE Pink Hill Road, Blue Springs, MO:  Employees were exposed to fire and explosion hazards. This was last demonstrated on or about September 15, 2023, and at times prior thereto, when employees were engaged in liquid petroleum gas (propane) activities including but not limited to residential properties. Employees responding to calls of service including gas leak(s) were not provided with all necessary information including, but not limited to a product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals. The employer failed to ensure that at 500-gallon tank containing liquefied petroleum gas (LP-Gas, LPG, Propane) was not labeled as to its contents or provided necessary physical or health hazards. Employees were exposed to fire and explosion hazards when working with propane gas which is a flammable gas.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Ferrellgas INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346982465.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.