Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HD EXTERIORS, LLC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of HD EXTERIORS, LLC. in 1201 WALNUT BOTTOM ROAD, CARLISLE, PA 17015 (NAICS 238170). OSHA activity number 347017659.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HD Exteriors, LLC. — free Get an email when a new federal OSHA severe-injury report for HD Exteriors, LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
HD EXTERIORS, LLC.
Site address
1201 WALNUT BOTTOM ROAD
City
CARLISLE
State
PA
ZIP
17015
Mailing
1809 MOUNT PLEASANT ROAD, MOUNT JOY, PA 17552
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.454 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 25, 2024
Abate by
Apr 30, 2024
Penalty
Initial $4,839 · Current $6,400
1926.454(c)(3):  The employer did not to retrain employees that showed indications through work performance of not retaining the requisite proficiency:   (a) 1201 Walnut Bottom Road, Carlisle, PA - End of building  - Employee  installed vinyl siding from a pump jack scaffolding system 18 feet above grade without  fall protection on the ends and back jack, on or about October 4, 2023.  (b) 1201 Walnut Bottom Road, Carlisle, PA - Front of building - Employee installed blue vinyl siding from a pump jack scaffolding system 18  feet above grade without  fall protection on the ends and back, on or about October 4, 2023.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $6400
  • — Z (S) $4839

1926.451 E08

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 25, 2024
Abate by
Feb 21, 2024
Penalty
Initial $4,839 · Current $0 Reduced
29 CFR  1926.451(e)(8):Direct access to or from another surface was used when the scaffold was more than 14 inches (36 cm) horizontally and/or 24 inches (61 cm) vertically from the other surface:  (a) 1201 Walnut Bottom Road, Carlisle, PA - Jobsite -  At the end of the day an employee lowered one end of  the pump jack scaffolding system,  to a second story window to egress platform through a  window, where the direct access was approximately 19 inches, on or about October 4, 2023.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4839

1926.452 J02

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Jan 25, 2024
Abate by
Feb 21, 2024
Penalty
Initial $2,765 · Current $0 Reduced
29 CFR  1926.452(j)(2):Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.  (a) 1201 Walnut Bottom Road, Carlisle, PA - End of building - Employee installed vinyl siding from a pump jack scaffolding system, bracing was not secured at the bottom of poles, on or about October 4, 2023.  (b) 1201 Walnut Bottom Road, Carlisle, PA - Front of building  -Employee installed blue vinyl siding from a pump jack scaffolding system, bracing was not secured at the bottom of poles, on or about October 4, 2023.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2765