MANGILAO, GU —
OSHA Inspection: 3R INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of 3R INCORPORATED in LOT 27-2-R1 TR 293 LATTE HEIGHTS, MANGILAO, GU 96923 (NAICS 236115). OSHA activity number 347045783.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 3R INCORPORATED
- Site address
- LOT 27-2-R1 TR 293 LATTE HEIGHTS
- City
- MANGILAO
- State
- GU
- ZIP
- 96923
- Mailing
- PO BOX 7693, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Nov 13, 2023
- Abate by
- Nov 24, 2023
- Penalty
- Initial $3,036 · Current $2,125 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Frontside of Building: Employees were building concrete forms from a scaffold that was not fully planked. Employees were exposed to fall hazards.
Recent events (2)
- — I (S) $2125.2
- — Z (S) $3036
1926.501 B01
- Issued
- Nov 13, 2023
- Abate by
- Nov 24, 2023
- Penalty
- Initial $3,795 · Current $2,657 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Front side of the roof: Employees pulling rebar onto a 10-foot roof were not protected by a guard rail, safety net, or personal fall arrest system. Employees were exposed to fall hazards.
Recent events (2)
- — I (S) $2656.5
- — Z (S) $3795
1926.1053 B01
- Issued
- Nov 13, 2023
- Abate by
- Nov 24, 2023
- Penalty
- Initial $3,795 · Current $2,657 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. Backside of the building: The extension ladder used to access the roof did not extend at least 3 feet above the landing surface. Employees were exposed to fall hazards. b. Frontside of the building: The ladder used to access the scaffolding did not extend at least 3 feet above the landing surface. Employees were exposed to fall hazards.
Recent events (2)
- — I (S) $2656.5
- — Z (S) $3795
1926.25 A
- Issued
- Nov 13, 2023
- Abate by
- Nov 24, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: Front side of building: lumber with protruding nails and other debris was not kept clear from the front of the building and around the scaffold access ladder. Employees were exposed to laceration and tripping hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.502 B02
- Issued
- Nov 13, 2023
- Abate by
- Nov 24, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members such as outlined in 1926.502(b)(2)(i)-(iv) of this section were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high. Back side of the roof: The guardrail system was missing a mid-rail. Employees were exposed to fall hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1053 B16
- Issued
- Nov 13, 2023
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. Front side of building: The step ladder used to access the scaffolding was missing the support side and the top rung. Employees were exposed to fall hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at 3R Incorporated
View 3R Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347045783.