RADFORD, VA —
OSHA Inspection: BAE SYSTEMS ORDNANCE SYSTEMS INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BAE SYSTEMS ORDNANCE SYSTEMS INC. in 4050 PEPPERS FERRY RD NW, RADFORD, VA 24141 (NAICS 325920). OSHA activity number 347059263.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BAE SYSTEMS ORDNANCE SYSTEMS INC.
- Site address
- 4050 PEPPERS FERRY RD NW
- City
- RADFORD
- State
- VA
- ZIP
- 24141
- Mailing
- 4050 PEPPERS FERRY RD NW, RADFORD, VA 24141
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325920
- Employees
- 1135
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.29 F05
- Issued
- Mar 26, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $7,835 · Current $7,835
General-duty citation text
29 CFR 1910.29(f)(5): Handhold. The employer did not ensure that handrails have the shape and dimension necessary so that employees can grasp the handrail firmly: a) Radford Army Ammunition Plant Sulfuric acid area: On or about 10/24/2023, employees are exposed to a possible fall hazard resulting from top stair rails not having the shape and dimension to firmly grasp the rail. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $7835
1910.219 C02 I
- Issued
- Mar 26, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $9,218 · Current $9,218
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) Radford Army Ammunition Plant Piccolo small motor shack: On or about 10/25/2023, motor M622 shaft assembly was not fully guarded as a result exposed employees to a possible hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $9218
1910.29 B01
- Issued
- Mar 26, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(b)(1): The employer did not ensure that guardrail systems met the requirement that the top edge height of top rails, or equivalent guardrail system members, that are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. The top edge height may exceed 45 inches (114 cm), provided the guardrail system meets all other criteria of paragraph (b) of this section (see Figure D-11 of this section): a) Radford Army Ammunition Plant Piccolo Deck: On or about 10/25/2023, the top guardrail was not 42 inches in that one side of the railing was hanging therefore could possibly expose employees to a 5ft fall hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $0
1910.146 C01
- Issued
- Mar 26, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: a) Radford Army Ammunition Plant: On or about 10/25/2023, the employer did not evaluate the Oleum Utility Vault to determine if the space was a permit-required confined space. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $0
1910.146 C02
- Issued
- Mar 26, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: a) Radford Army Ammunition Plant Sulfuric Acid Tanks: On or about 10/25/2023, the employer failed to post a danger sign at the T-105 tank manhole access. b) Radford Army Ammunition: On or about 10/25/2023, the employer failed to post a danger sign at the access into the Oleum Utility Vault. NOTE: A sign reading DANGER-PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or using other similar language would satisfy the requirement for a sign. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $0
1910.304 E01 II
- Issued
- Mar 26, 2024
- Abate by
- Apr 19, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(e)(1)(ii): The service disconnecting means did not plainly indicate whether it is in the open or closed position: a) Radford Army Ammunition Plant Piccolo area: On or about 10/25/2023, the 440-volts Master switch used to supply power to the pumps motor room, the open or closed positions eroded. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $0
More inspections at BAE Systems Ordnance Systems INC.
View BAE Systems Ordnance Systems INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325920)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347059263.